15 Luis Garza-Vigas Ternium
-
Upload
jaime-coronell -
Category
Documents
-
view
74 -
download
7
Transcript of 15 Luis Garza-Vigas Ternium
![Page 1: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/1.jpg)
NORMAS PARA VIGAS ELECTROSOLDADASNORMAS PARA VIGAS ELECTROSOLDADASNORMAS PARA VIGAS ELECTROSOLDADASNORMAS PARA VIGAS ELECTROSOLDADAS
Luis Garza Vásquez I.C., M.I.Luis Garza Vásquez I.C., M.I.Luis Garza Vásquez I.C., M.I.Luis Garza Vásquez I.C., M.I.
![Page 2: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/2.jpg)
Perfiles I
Perfiles Laminados Perfiles Armados
Soldados
Perfiles Armados
Electrosoldados
![Page 3: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/3.jpg)
Perfiles
CANALESH DE ALA ANCHA
I DE ALAS PARALELAS I DE ALAS INCLINADAS
• S
• IPN• W
• IPE
• WF
• HP
• HEA
• C
• UPN
![Page 4: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/4.jpg)
PERFILES
ELECTROSOLDADOS:
¡NO ESTABAN EN NSR-10!
Vgr. PROPERCA
![Page 5: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/5.jpg)
AHORA SI…..
![Page 6: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/6.jpg)
Revisión ASTM 769
Elemento Nomenclatura Min
mm
Max
mm
ALETA bf 12.7 300
tf 1.5 12.7
ALMA d 50 600
tw 1.5 10
VIP: � Ok!
![Page 7: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/7.jpg)
CLASE:
No tienen filete → + vulnerables a cargas dinámicas.
Clase:
1. Cargas Estáticas
– ww>1.1tw
2. Cargas dinámicas
– ww>1.3tw y sin empates
![Page 8: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/8.jpg)
Prueba de “pelado”En cada extremo o cada hora
![Page 9: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/9.jpg)
![Page 10: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/10.jpg)
MATERIAL
• ASTM A572 gr. 50 VIP: � Ok!
• ASTM A1011 VIP: � Ok!
![Page 11: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/11.jpg)
MATERIAL
• Los ensayos de tensión deben ser hecho por el fabricante del rollo
• El fabricante de los perfiles debe hacer al menos uno a cada rollo
![Page 12: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/12.jpg)
ENSAYO
TENSION EN T
• Cada soldadura
por lote
• Falla a tensión del
alma OK!
• Falla a cortante
aleta OK!
• Falla soldadura
NPP!
![Page 13: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/13.jpg)
Relaciones
Ancho-Espesor
![Page 14: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/14.jpg)
Relaciones
Ancho-Espesor
¡Y armados!
![Page 15: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/15.jpg)
Relaciones
Ancho-EspesorValores límite de la relación
ancho/espesor
ELEMENTO
Tabla F.2.2.4-1b Tabla 3.4-1
λP λdm λda
(compacto/no compacto)Miembros de Ductilidad
ModeradaMiembros de Ductilidad
Alta
ALA0.38*√(E/Fy) 0.38*√(E/Fy) 0.30*√(E/Fy)
9.15 9.15 7.22
ALMA3.76*√(E/Fy) 1.49*√(E/Fy) 1.49*√(E/Fy)
90.55 35.88 35.88
VIP 180 x 14.7 � � �
VIP 230 x 16.4 � � �
VIP 270 x 24.9 � � �
VIP 320 x 30.6 � � �
VIP 380 x 38.1 � � �
VIP 430 x 47.4 � � �
VIP 460 x 56.4 � � �
![Page 16: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/16.jpg)
MIEMBROS
COMPUESTOS
![Page 17: 15 Luis Garza-Vigas Ternium](https://reader034.fdocuments.mx/reader034/viewer/2022042516/55721317497959fc0b9193a7/html5/thumbnails/17.jpg)
¿Y los esfuerzos
residuales?
• En NSR-98 eran mayores que para perfiles laminados: 115 vs 70MPa
• Ahora es 0.3Fy
• ¡Quedaron a mano!