GAGEAIAG

13
Estudio de la capacidad del instrumento (metodo largo) Fecha Estudio Persona responsable Departamento Especificaciones EI= 9.23 ES= 9.29 Tipo de gage Tolerancia= 9.23 - 9.29 = 0.06 No de gage uestra (cm) Operador 1 Operador 2 1 tri 9.28 9.242 9.276 0.038 9.278 9.246 9.27 0.032 2 coraz 9.26 9.248 9.246 0.014 9.272 9.252 9.252 0.02 3 estre 9.262 9.264 9.26 0.004 9.26 9.262 9.264 0.004 4 cuadra 9.27 9.25 9.252 0.02 9.27 9.26 9.268 0.01 5 circul 9.28 9.278 9.276 0.004 9.282 9.28 9.27 0.012 6 espira 9.276 9.28 9.256 0.024 9.254 9.27 9.286 0.032 7 linea 9.25 9.26 9.276 0.026 9.28 9.25 9.25 0.03 8 feliz 9.26 9.278 9.276 0.018 9.278 9.286 9.284 0.008 9 9.278 9.276 9.267 0.011 9.28 9.276 9.267 0.013 10 9.265 9.267 9.26 0.007 9.27 9.278 9.28 0.01 Total 92.681 92.724 92.643 Ra 0.0166 92.66 Rb 0.0171 92.645 92.691 suma 277.97 278.08 Xa 9.2656 Xb 9.2692 Xc Ra 0.0166 Max X 9.2692 LSC = R*D Rb 0.0171 Min X 9.2656 LSC = (0.0168 Rc X dif 0.0035 0.0433 Suma 0.0337 X 0.0168 Repetabilidad (variacion del equipo) VE= R*k1 = 0.0168 3.05 = 0.0512 2 K1 4.56 k2 3.65 n=numero de p t=numero de en Reprodicibilidad (variacion del operador) vo= Ensayo 1 Ensayo 2 Ensayo 3 Ensayo Ensayo 1 Ensayo 2 Ensayo 3 Ensayo Ensayo 1 K1 ensayo s y K2 operad ores √((( ) 2)^2 )− (())/ ^2=

description

gage

Transcript of GAGEAIAG

Hoja1Estudio de la capacidad del instrumento(metodo largo)

Fecha 24 de marzo 2015Estudio Medicin tornillosPersona responsable Departamento Especificaciones EI=9.23ES=9.29Tipo de gageTolerancia=9.23-9.29=0.06No de gage

Muestra (cm) Operador 1Operador 2Operador 3Ensayo 1Ensayo 2Ensayo 3Ensayo Ensayo 1Ensayo 2Ensayo 3Ensayo Ensayo 1Ensayo 2Ensayo 3Ensayo 1 tri9.289.2429.2760.0389.2789.2469.270.0322 coraz9.269.2489.2460.0149.2729.2529.2520.023 estre9.2629.2649.260.0049.269.2629.2640.0044 cuadra9.279.259.2520.029.279.269.2680.015 circul9.289.2789.2760.0049.2829.289.270.0126 espira9.2769.289.2560.0249.2549.279.2860.0327 linea9.259.269.2760.0269.289.259.250.038 feliz9.269.2789.2760.0189.2789.2869.2840.00899.2789.2769.2670.0119.289.2769.2670.013109.2659.2679.260.0079.279.2789.280.01Total 92.68192.72492.643Ra0.016692.66Rb0.0171Rc92.64592.691suma277.969278.075Xa9.2656333333Xb9.2691666667Xc

Ra0.0166Max X9.2691666667LSC=R*DEnsayos DRb0.0171Min X9.2656333333LSC=(0.0168)(2.57)23.27RcX dif0.00353333330.043304532.57Suma0.0337X0.01685Repetabilidad (variacion del equipo)VE=R*k1=0.01683.05=0.05124K1 ensayos y K2 operadores23Analisis en % de tolerancias K14.563.05%VE=100*VE/Toleranciak23.652.7%VO=100*VO/Tolerancian=numero de partes PVT=%R&Rt=numero de ensayos Reprodicibilidad (variacion del operador)vo===VO=5.15Criterios de aceptacinDebajo de 10% -Excelente procesoRepetibilidad y reproducibilidadDe 10% a 20%-Bueno, aceptableDe 20% a 30%-AceptableEM= R&R=Arriba de 30%-Inaceptable y debe ser corregido=R&R=5.15

ejercicio del libro Estudio de la capacidad del instrumento(metodo largo)

Fecha 24 de marzo 2015Estudio Medicin tornillosPersona responsable Departamento Especificaciones EI=25ES=40Tipo de gageTolerancia=40-25=15No de gage

Muestra (cm) Operador 1Operador 2Operador 3Ensayo 1Ensayo 2Ensayo 3RangoEnsayo 1Ensayo 2Ensayo 3Rango Ensayo 1Ensayo 2Ensayo 3Ensayo 136.236.30.135.8350.836.134.81.3235.3350.335.635.10.535.734.71330.830.60.230.428.91.530.229.21429.829.60.230.229.90.328.330.11.853231.70.331.131.70.630.131.71.6630.729.7130.930.40.529.829.50.3733.432.4132.932.10.833.431.22.2837.136.50.636.736.20.53635.50.5930.130.50.43029.70.329.130.21.11034.634.20.434.133.70.433.634.20.6Total 330327.7322.3326.5^Ra0.45322.7^Rb0.62321.1^Rc 1.14

suma656.5Suma650.4Suma643.4^Xa32.825^Xb32.52^Xc32.17

^Ra0.45Max ^X32.825LCS=^R*D4Ensayos D^Rb0.62Min ^X32.17LSC=2.408923.27^Rc1.14^X dif0.65532.57Suma2.21^R0.7366666667Repetabilidad (variacion del equipo)VE=^R*k1=0.73666666674.56=3.3592K1 ensayos y K2 operadores23Analisis en % de tolerancias K14.563.05%VE=100*VE/Toleranciarepet=VE=0.6522718447k23.652.7%VO=100*VO/Tolerancia5.15n=numero de partes PVT=%R&Rt=numero de ensayos Reprodicibilidad (variacion del operador)vo=1.6010562195Analisis en % de tolerancias%VE=100(VE)/Tolerancia=22.3946666667%%VO=100(VO)/Tolerancia=10.67370813%repod=VO=0.3108847028P/T=%R&R=24.8082%5.15Criterios de aceptacinDebajo de 10% -Excelente procesoRepetibilidad y reproducibilidadDe 10% a 20%-Bueno, aceptableDe 20% a 30%-AceptableEM= R&R=3.7212371139Arriba de 30%-Inaceptable y debe ser corregido=R&R=0.72257031345.15

MinitabOperadorEnsayo Valor OperadorEnsayo Valor OperadorEnsayo Valor 1136.22135.83136.11135.32135.63135.71130.82130.43130.21129.82130.23128.311322131.13130.11130.72130.93129.81133.42132.93133.41137.12136.731361130.121303129.11134.62134.13133.61236.322353234.812352235.13234.71230.62228.93229.21229.62229.93230.11231.72231.73231.71229.72230.43229.51232.42232.13231.21236.52236.23235.51230.52229.73230.21234.22233.73234.22135.82135.62130.42130.22131.12130.92132.92136.721302134.122352235.12228.92229.92231.72230.42232.12236.22229.72233.73136.13135.73130.23128.33130.13129.83133.431363129.13133.63234.83234.73229.23230.13231.73229.53231.23235.53230.23234.2

Hoja4PARTESOperador Medicion 110.0045210.0045310.0045410.005510.0045610.005710.005810.005910.0051010.004110.0045210.0055310.0045410.005510.0045610.0055710.0045810.005910.00451010.004110.0045210.0045310.0045410.0045510.0045610.0045710.0045810.005910.0051010.004120.0045220.0055320.0045420.005520.004620.006720.0055820.005920.00451020.004120.0045220.005320.0045420.005520.0045620.005720.0045820.005920.00451020.004120.0045220.0045320.0045420.005520.004620.005720.005820.005920.0051020.004130.005230.0055330.0045430.005530.0045630.005730.0045830.006930.00551030.0045130.0045230.0045330.0045430.005530.0045630.005730.005830.005930.00451030.0045130.0045230.0045330.004430.005530.004630.005730.005830.005930.00451030.0045