DISEO DE COLUMNA CUADRADA CON CARGA AXIAL
PD = 136,200.00 kg. Carga Axial Muerta
PL = 227,000.00 kg. Carga Axial Viva
f'c = 280.00 kg/cm2
f'y = 4,220.00 kg/cm2
r = 2% Valor % de Ascero Longitudinal DIAMETRO AREA
2 1/4" 0.635 0.32
FACTORIZANDO CARGA 3 3/8" 0.953 0.71
Pu = 526,640.00 kg. 4 1/2" 1.270 1.27
5 5/8" 1.588 1.98
DETERMINAR AREA BRUTA DE LA COLUMNA 6 3/4" 1.905 2.85
Ag = 3,188.42 cm2 Area Bruta Calculada 8 1" 2.540 5.07
9 1 1/8" 2.858 6.41
DIMENSIONES DE COLUMNA 10 1 1/4" 3.175 7.92
11 1 3/8" 3.493 9.58
b = 60 cm 12 1 1/2" 3.810 ####
h = 60 cm % del Acero en Columnas =
Ag = 3600 cm2 Area Bruta Total. % minimo = 1%
% maximo = 8%
AREA DE ACERO % del Acero en Columnas en la Practica Real
As = 72 cm2 % minimo = 1%
r = 2.00% % maximo = 3%
ARMADO DE COLUMNA
4 1 1/2" 45.6 cm2
4 1 1/4" 31.68 cm2
77.28 cm2
DISEO DE COLUMN BIAXIAL
Pu= 1,200.00 Kn 122,364.00 kg 1Kn= 101.97 kg
Mux= 180.00 Kn.m 18,354.60 kg.m 1Mpa= 10.1967982 kg/cm2
Muy= 75.00 Kn.m 7,647.75 kg.m
f'c = 28.00 Mpa 285.51 kg/cm2
f'y = 420.00 Mpa 4,282.66 kg/cm2
r = 2% Valor % de Ascero Longitudinal
ex = 0.063 m
ey = 0.150 m
ex < ey Col. Rectangular en donde la Direccion Y es mayor a la Direc. X
Por lo tanto la direccion que controla el diseo es la direccin Y
Ag = 727.44 cm2 Area Bruta Calculada
DX = 30.00 cm
DY = 50.00 cm
Ag = 1,500.00 cm2
DY/DX= 1.67 a =Pu/(Ag x f'c) 0.0
ey/ex = 2.38 b 0.6
ey/ex > DY/DX Col. Rectangular en donde la Direccion Y es mayor a la Direc. X
a = 0.286
b = 0.89
ef = 0.24
Mu = 29,367.36 kg.m
-
PERIM.PESO DIAMTEROR
0.25 0.64 0.32 1
0.25 0.56 0.95 0.48 0.71
3.99 0.99
4.99 1.55
5.98 2.24
7.98 3.98
kg/cm2
rbb
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2
0.7 0.8 0.9 0.9 0.8 0.7 0.6 0.6 0.6 0.5 0.5 0.4