1.4
CANALES Area (ha) Caudal (l/s)
PRINCIPAL 96.853 135.5942 SEC10 8.398 11.7572
SEC1 2.368 3.3152 132.3 1 1.483 2.0762
SEC2 3.384 4.7376 127.5 2 1.969 2.7566
1 0.766 1.0724 3 1.132 1.5848
2 1.846 2.5844 4 2.258 3.1612
SEC3 4.225 5.915 121.6 SEC11 3.19 4.466
SEC4 2.237 3.1318 118.4946 SEC12 13.533 18.9462
1 0.668 0.9352 1 6.785 9.499
2 0.418 0.5852 A 0.555 0.777
SEC5 2.144 3.0016 115.5 B 0.912 1.2768
1 1.772 2.4808 C 0.997 1.3958
2 0.372 0.5208 2 1.2 1.68
SEC6 17.843 24.9802 90.5 3 2.961 4.1454
1 1.947 2.7258 SEC13 8.45 11.83
2 2.918 4.0852 1 0.856 1.1984
3 3.448 4.8272 2 1.271 1.7794
4 3.25 4.55 3 0.687 0.9618
5 2.648 3.7072 4 0.699 0.9786
6 1.728 2.4192 5 0.776 1.0864
7 1.322 1.8508 6 0.508 0.7112
8 0.582 0.8148 7 0.508 0.7112
SEC7 16.644 23.3016 67.2
1 3.942 5.5188
2 3.586 5.0204
3 4.863 6.8082
4 2.344 3.2816
5 1.909 2.6726
6 1.586 2.2204
SEC8 3.254 4.5556 62.7
SEC9 2.937 4.1118 58.5
1 1.986 2.7804
2 0.951 1.3314
46.8
42.3
23.4
11.5
Caudal especifico (l/s/ha)
TRAMO
CANAL 1
Cota Inicial= 2186.00 [m.s.n.m.] 0.00
Cota final= 2185.880 [m.s.n.m.] 32.44
L= 32.44 [m]
Qd = 0.136 m3/s
So = 0.00370 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.538 m. Asumimos Constructivamente b = 0.60 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.24 m
0.038 = 0.038 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.145 m2
Perímetro:
P= 1.084 m
Radio Hidráulico:
Rh= 0.134 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.934 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.194 m2
Pmin= 1.246 m2
Rh= 0.156 m2Smin= 0.0017 m/m
Datos de iniciales
Prog.inicial=0+0
Prog.Final=0+
[Concreto ]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Pendiente máxima
Amax= 0.045 m2
Pmax= 0.751 m2
Rh= 0.060 m2
Smax= 0.1102 m/m
Pendiente normal del canal:
So= 0.0037 m/m Ok Cumple!!!
Hf= 0.119 m
Numero de Froude
V= 0.934 m/s
A= 0.145 m2
T= 0.60 m2
Fr= 0.61 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.60 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.4m
0.24 m
0.6 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
CANAL 2
Cota Inicial= 2184.07 [m.s.n.m.] 86.23
Cota final= 2184.040 [m.s.n.m.] 100
L= 13.77 [m]
Qd = 0.136 m3/s
So = 0.00218 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.594 m. Asumimos Constructivamente b = 0.60 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.29 m
0.049 = 0.049 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.174 m2
Perímetro:
P= 1.181 m
Radio Hidráulico:
Rh= 0.148 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7776 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.194 m2
Pmin= 1.246 m2
Rh= 0.156 m2Smin= 0.0017 m/m
Pendiente máxima
Amax= 0.045 m2
Pmax= 0.751 m2
Datos de iniciales
Prog.inicial=0+0
Prog.Final=0+
[Concreto ]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Rh= 0.060 m2
Smax= 0.1102 m/m
Pendiente normal del canal:
So= 0.0022 m/m Ok Cumple!!!
Hf= 0.031 m
Numero de Froude
V= 0.778 m/s
A= 0.174 m2
T= 0.60 m2
Fr= 0.4605 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.15 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.60 m
h = 0.45 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.45m
0.29 m
0.6 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
CANAL 3
Cota Inicial= 2184.04 [m.s.n.m.] 100.00
Cota final= 2183.960 [m.s.n.m.] 112.81
L= 12.81 [m]
Qd = 0.132 m3/s
So = 0.00625 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.483 m. Asumimos Constructivamente b = 0.60 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.19 m
0.028 = 0.028 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.117 m2
Perímetro:
P= 0.989 m
Radio Hidráulico:
Rh= 0.118 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 1.1348 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.189 m2
Pmin= 1.230 m2
Rh= 0.154 m2Smin= 0.0017 m/m
Pendiente máxima
Amax= 0.044 m2
Pmax= 0.747 m2
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Rh= 0.059 m2
Smax= 0.1131 m/m
Pendiente normal del canal:
So= 0.0064 m/m Ok Cumple!!!
Hf= 0.082 m
Numero de Froude
V= 1.135 m/s
A= 0.117 m2
T= 0.60 m2
Fr= 0.8219 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.10 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.60 m
h = 0.35 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.35m
0.19 m
0.6 m
CANAL 4
Cota Inicial= 2181.00 [m.s.n.m.] 190.00
Cota final= 2180.780 [m.s.n.m.] 260
L= 70.00 [m]
Qd = 0.132 m3/s
So = 0.00314 [m/m]
n = 0.017
Perdida de carga
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
Cota inicial
Cota Final
solera
So
L
?h
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.549 m. Asumimos Constructivamente b = 0.60 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.25 m
0.040 = 0.040 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.151 m2
Perímetro:
P= 1.103 m
Radio Hidráulico:
Rh= 0.137 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.8771 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.189 m2
Pmin= 1.230 m2
Rh= 0.154 m2Smin= 0.0017 m/m
Pendiente máxima
Amax= 0.044 m2
Pmax= 0.747 m2
Rh= 0.059 m2Smax= 0.1131 m/m
Pendiente normal del canal:
So= 0.0032 m/m Ok Cumple!!!
Perdida de carga
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Hf= 0.221 m
Numero de Froude
V= 0.877 m/s
A= 0.151 m2
T= 0.60 m2
Fr= 0.5585 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.13 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.60 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.15m
0.4m
0.25 m
0.6 m
CANAL 5
Cota Inicial= 2180.78 [m.s.n.m.] 260.00
Cota final= 2180.540 [m.s.n.m.] 281.9
L= 21.90 [m]
Qd = 0.128 m3/s
So = 0.01096 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
𝐵𝐿 =𝑦
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
b = 0.428 m. Asumimos Constructivamente b = 0.45 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.21 m
0.022 = 0.021 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.095 m2
Perímetro:
P= 0.873 m
Radio Hidráulico:
Rh= 0.109 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 1.3411 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.182 m2
Pmin= 1.260 m2
Rh= 0.145 m2Smin= 0.0019 m/m
Pendiente máxima
Amax= 0.043 m2
Pmax= 0.639 m2
Rh= 0.067 m2Smax= 0.0965 m/m
Pendiente normal del canal:
So= 0.0100 m/m Ok Cumple!!!
Hf= 0.219 m
Numero de Froude
V= 1.341 m/s
A= 0.095 m2
T= 0.45 m2
Fr= 0.9315 Régimen Subcrítico
Perdida de carga
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
Cálculo del Borde libre:
BL = 0.11 m
Se asumirá un borde libre constructivo de: BL = 0.19 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.45 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.19m
0.4m
0.21 m
0.45 m
CANAL 6
Cota Inicial= 2178.96 [m.s.n.m.] 328.36
Cota final= 2178.850 [m.s.n.m.] 360
L= 31.64 [m]
Qd = 0.128 m3/s
So = 0.00348 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.531 m. Asumimos Constructivamente b = 0.55 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.26 m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
𝐵𝐿 =𝑦
2
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
0.037 = 0.037 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.142 m2
Perímetro:
P= 1.067 m
Radio Hidráulico:
Rh= 0.133 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.8965 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.182 m2
Pmin= 1.212 m2
Rh= 0.150 m2Smin= 0.0018 m/m
Pendiente máxima
Amax= 0.043 m2
Pmax= 0.705 m2
Rh= 0.060 m2
Smax= 0.1099 m/m
Pendiente normal del canal:
So= 0.0034 m/m Ok Cumple!!!
Hf= 0.108 m
Numero de Froude
V= 0.897 m/s
A= 0.142 m2
T= 0.55 m2
Fr= 0.5629 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.13 m
Se asumirá un borde libre constructivo de: BL = 0.14 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
Perdida de carga
𝐵𝐿 =𝑦
2
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b = 0.55 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.14m
0.4m
0.26 m
0.55 m
CANAL 7
Cota Inicial= 2178.85 [m.s.n.m.] 360.00
Cota final= 2178.790 [m.s.n.m.] 378.78
L= 18.78 [m]
Qd = 0.122 m3/s
So = 0.00319 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.530 m. Asumimos Constructivamente b = 0.55 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.26 m
0.037 = 0.037 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.142 m2
Perímetro:
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
Cota inicial
Cota Final
solera
So
L
?h
P= 1.067 m
Radio Hidráulico:
Rh= 0.133 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.8551 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.174 m2
Pmin= 1.182 m2
Rh= 0.147 m2
Smin= 0.0018 m/m
Pendiente máxima
Amax= 0.041 m2
Pmax= 0.697 m2
Rh= 0.058 m2
Smax= 0.1155 m/m
Pendiente normal del canal:
So= 0.0031 m/m Ok Cumple!!!
Hf= 0.058 m
Numero de Froude
V= 0.855 m/s
A= 0.142 m2
T= 0.55 m2
Fr= 0.5369 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.13 m
Se asumirá un borde libre constructivo de: BL = 0.14 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.55 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
Perdida de carga
𝐵𝐿 =𝑦
2
𝑃 𝑏 + 2 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
0.14m
0.4m
0.26 m
0.55 m
CANAL 8
Cota Inicial= 2170.14 [m.s.n.m.] 566.97
Cota final= 2169.950 [m.s.n.m.] 600
L= 33.03 [m]
Qd = 0.122 m3/s
So = 0.00575 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.475 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.23 m
0.027 = 0.027 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.113 m2
Perímetro:
P= 0.950 m
Radio Hidráulico:
Rh= 0.118 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
Cota inicial
Cota Final
solera
So
L
?h
Velocidad en la sección
V= 1.0804 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.174 m2
Pmin= 1.195 m2
Rh= 0.145 m2
Smin= 0.0019 m/m
Pendiente máxima
Amax= 0.041 m2
Pmax= 0.662 m2
Rh= 0.061 m2
Smax= 0.1078 m/m
Pendiente normal del canal:
So= 0.0058 m/m Ok Cumple!!!
Hf= 0.192 m
Numero de Froude
V= 1.080 m/s
A= 0.113 m2
T= 0.50 m2
Fr= 0.7270 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.11 m
Se asumirá un borde libre constructivo de: BL = 0.17 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.17m
0.4m
0.23 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
0.5 m
CANAL 9
Cota Inicial= 2169.95 [m.s.n.m.] 600.00
Cota final= 2169.600 [m.s.n.m.] 692.44
L= 92.44 [m]
Qd = 0.119 m3/s
So = 0.00379 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.509 m. Asumimos Constructivamente b = 0.55 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.24 m
0.033 = 0.033 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.131 m2
Perímetro:
P= 1.025 m
Radio Hidráulico:
Rh= 0.127 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.9077 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.169 m2
Pmin= 1.166 m2
Rh= 0.145 m2Smin= 0.0019 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Pendiente máxima
Amax= 0.040 m2
Pmax= 0.694 m2
Rh= 0.057 m2
Smax= 0.1187 m/m
Pendiente normal del canal:
So= 0.0037 m/m Ok Cumple!!!
Hf= 0.343 m
Numero de Froude
V= 0.908 m/s
A= 0.131 m2
T= 0.55 m2
Fr= 0.5949 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.55 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.4m
0.24 m
0.55 m
CANAL 10
Cota Inicial= 2167.55 [m.s.n.m.] 761.55
Cota final= 2167.000 [m.s.n.m.] 890
L= 128.45 [m]
Perdida de carga
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
Cota inicial
Cota Final
solera
So
L
?h
Qd = 0.119 m3/s
So = 0.00428 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.497 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.25 m
0.031 = 0.031 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.124 m2
Perímetro:
P= 0.998 m
Radio Hidráulico:
Rh= 0.125 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.9519 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.169 m2
Pmin= 1.177 m2
Rh= 0.144 m2Smin= 0.0019 m/m
Pendiente máxima
Amax= 0.040 m2
Pmax= 0.658 m2
Rh= 0.060 m2Smax= 0.1107 m/m
Pendiente normal del canal:
So= 0.0042 m/m Ok Cumple!!!
[Concreto ]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 𝑅 2 3
2
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Hf= 0.540 m
Numero de Froude
V= 0.952 m/s
A= 0.124 m2
T= 0.50 m2
Fr= 0.6091 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.15m
0.4m
0.25 m
0.5 m
CANAL 11
Cota Inicial= 2161.11 [m.s.n.m.] 940.76
Cota final= 2160.940 [m.s.n.m.] 980.01
L= 39.25 [m]
Qd = 0.119 m3/s
So = 0.00433 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Concreto ]
Perdida de carga
𝐵𝐿 =𝑦
2
𝑜
𝐴 ∗ 𝑅ℎ 2 3
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
Cota inicial
Cota Final
solera
So
L
?h
b = 0.496 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.24 m
0.030 = 0.031 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.121 m2
Perímetro:
P= 0.986 m
Radio Hidráulico:
Rh= 0.123 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.9758 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.169 m2
Pmin= 1.177 m2
Rh= 0.144 m2Smin= 0.0019 m/m
Pendiente máxima
Amax= 0.040 m2
Pmax= 0.658 m2
Rh= 0.060 m2Smax= 0.1107 m/m
Pendiente normal del canal:
So= 0.0045 m/m Ok Cumple!!!
Hf= 0.176 m
Numero de Froude
V= 0.976 m/s
A= 0.121 m2
Perdida de carga
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝐴
T= 0.50 m2
Fr= 0.6322 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.4m
0.24 m
0.5 m
CANAL 12
Cota Inicial= 2160.94 [m.s.n.m.] 980.01
Cota final= 2160.650 [m.s.n.m.] 70.22
L= 90.21 [m]
Qd = 0.116 m3/s
So = 0.00321 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.520 m. Asumimos Constructivamente b = 0.55 m.
Cálculo del Tirante Normal con la base asumida
Datos de iniciales
Prog.inicial=0+
Prog.Final=1+0
[Concreto ]
𝐵𝐿 =𝑦
2
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
Si Yn = 0.25 m
0.035 = 0.035 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.136 m2
Perímetro:
P= 1.046 m
Radio Hidráulico:
Rh= 0.130 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.8475 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.165 m2
Pmin= 1.150 m2
Rh= 0.143 m2Smin= 0.0019 m/m
Pendiente máxima
Amax= 0.039 m2
Pmax= 0.690 m2
Rh= 0.056 m2
Smax= 0.1220 m/m
Pendiente normal del canal:
So= 0.0031 m/m Ok Cumple!!!
Hf= 0.283 m
Numero de Froude
V= 0.848 m/s
A= 0.136 m2
T= 0.55 m2
Fr= 0.5436 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
Perdida de carga
𝐵𝐿 =𝑦
2
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
C = 0.60 m
Dimensiones Constructivas:
b = 0.55 m
h = 0.40 m
e = 0.2 m
Dimensionamiento Final:
0.15m
0.4m
0.25 m
0.55 m
CANAL 13
Cota Inicial= 2160.65 [m.s.n.m.] 70.22
Cota final= 2159.490 [m.s.n.m.] 530
L= 459.78 [m]
Qd = 0.091 m3/s
So = 0.00252 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.496 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.25 m
0.030 = 0.031 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Datos de iniciales
Prog.inicial=1+0
Prog.Final=1+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
Area:
A= 0.123 m2
Perímetro:
P= 0.991 m
Radio Hidráulico:
Rh= 0.124 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7379 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.129 m2
Pmin= 1.017 m2
Rh= 0.127 m2
Smin= 0.0022 m/m
Pendiente máxima
Amax= 0.030 m2
Pmax= 0.621 m2
Rh= 0.049 m2
Smax= 0.1466 m/m
Pendiente normal del canal:
So= 0.0025 m/m Ok Cumple!!!
Hf= 1.172 m
Numero de Froude
V= 0.738 m/s
A= 0.123 m2
T= 0.50 m2
Fr= 0.4757 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.12 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.40 m
e = 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
Dimensionamiento Final:
0.15m
0.4m
0.25 m
0.5 m
CANAL 14
Cota Inicial= 2159.49 [m.s.n.m.] 530.00
Cota final= 2159.430 [m.s.n.m.] 550.23
L= 20.23 [m]
Qd = 0.067 m3/s
So = 0.00297 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.431 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.19 m
0.021 = 0.021 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.093 m2
Perímetro:
P= 0.874 m
Radio Hidráulico:
Rh= 0.107 m
Datos de iniciales
Prog.inicial=1+
Prog.Final=1+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
Cota inicial
Cota Final
solera
So
L
?h
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7187 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.096 m2
Pmin= 0.884 m2
Rh= 0.109 m2
Smin= 0.0027 m/m
Pendiente máxima
Amax= 0.022 m2
Pmax= 0.590 m2
Rh= 0.038 m2Smax= 0.2037 m/m
Pendiente normal del canal:
So= 0.0029 m/m Ok Cumple!!!
Hf= 0.059 m
Numero de Froude
V= 0.719 m/s
A= 0.093 m2
T= 0.50 m2
Fr= 0.5307 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.09 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.35 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.35m
0.19 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
0.5 m
CANAL 15
Cota Inicial= 2156.83 [m.s.n.m.] 645.35
Cota final= 2156.660 [m.s.n.m.] 680
L= 34.65 [m]
Qd = 0.067 m3/s
So = 0.00491 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.392 m. Asumimos Constructivamente b = 0.40 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.19 m
0.017 = 0.016 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.078 m2
Perímetro:
P= 0.790 m
Radio Hidráulico:
Rh= 0.099 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.8624 m/s Ok Cumple!!!
Pendiente mínima
Datos de iniciales
Prog.inicial=1+
Prog.Final=1+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑉2
Cota inicial
Cota Final
solera
So
L
?h
Amín= 0.096 m2
Pmin= 0.880 m2
Rh= 0.109 m2
Smin= 0.0027 m/m
Pendiente máxima
Amax= 0.022 m2
Pmax= 0.512 m2
Rh= 0.044 m2
Smax= 0.1687 m/m
Pendiente normal del canal:
So= 0.0047 m/m Ok Cumple!!!
Hf= 0.163 m
Numero de Froude
V= 0.862 m/s
A= 0.078 m2
T= 0.40 m2
Fr= 0.6239 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.10 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.40 m
h = 0.35 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.35m
0.19 m
0.4 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
CANAL 16
Cota Inicial= 2156.66 [m.s.n.m.] 680.00
Cota final= 2156.350 [m.s.n.m.] 760
L= 80.00 [m]
Qd = 0.063 m3/s
So = 0.00387 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.399 m. Asumimos Constructivamente b = 0.50 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.16 m
0.017 = 0.017 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.080 m2
Perímetro:
P= 0.821 m
Radio Hidráulico:
Rh= 0.098 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7806 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.090 m2
Pmin= 0.858 m2
Rh= 0.104 m2Smin= 0.0029 m/m
Pendiente máxima
Amax= 0.021 m2
Pmax= 0.584 m2
Datos de iniciales
Prog.inicial=1+
Prog.Final=1+
[Concreto ]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Rh= 0.036 m2
Smax= 0.2203 m/m
Pendiente normal del canal:
So= 0.0039 m/m Ok Cumple!!!
Hf= 0.313 m
Numero de Froude
V= 0.781 m/s
A= 0.080 m2
T= 0.50 m2
Fr= 0.6219 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.08 m
Se asumirá un borde libre constructivo de: BL = 0.14 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.50 m
h = 0.30 m
e = 0.2 m
Dimensionamiento Final:
0.14m
0.3m
0.16 m
0.5 m
CANAL 17
Cota Inicial= 2156.35 [m.s.n.m.] 760.00
Cota final= 2155.450 [m.s.n.m.] 980
L= 220.00 [m]
Qd = 0.059 m3/s
So = 0.00409 [m/m]
n = 0.017
Datos de iniciales
Prog.inicial=1+
Prog.Final=1+
[Concreto ]
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
Cota inicial
Cota Final
solera
So
L
?h
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.385 m. Asumimos Constructivamente b = 0.40 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.19 m
0.016 = 0.016 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.076 m2
Perímetro:
P= 0.779 m
Radio Hidráulico:
Rh= 0.097 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7723 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.084 m2
Pmin= 0.818 m2
Rh= 0.102 m2Smin= 0.0030 m/m
Pendiente máxima
Amax= 0.020 m2
Pmax= 0.498 m2
Rh= 0.039 m2Smax= 0.1954 m/m
Pendiente normal del canal:
So= 0.0039 m/m Ok Cumple!!!
Perdida de carga
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota inicial
Cota Final
solera
So
L
?h
Hf= 0.848 m
Numero de Froude
V= 0.772 m/s
A= 0.076 m2
T= 0.40 m2
Fr= 0.5666 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.09 m
Se asumirá un borde libre constructivo de: BL = 0.16 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.40 m
h = 0.35 m
e = 0.2 m
Dimensionamiento Final:
0.16m
0.35m
0.19 m
0.4 m
CANAL 18
Cota Inicial= 2156.45 [m.s.n.m.] 980.00
Cota final= 2155.450 [m.s.n.m.] 200
L= 220.00 [m]
Qd = 0.047 m3/s
So = 0.00455 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
Datos de iniciales
Prog.inicial=1+
Prog.Final=2+
[Concreto ]
𝐵𝐿 =𝑦
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
b = 0.347 m. Asumimos Constructivamente b = 0.40 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.15 m
0.012 = 0.012 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.061 m2
Perímetro:
P= 0.707 m
Radio Hidráulico:
Rh= 0.087 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7623 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.067 m2
Pmin= 0.734 m2
Rh= 0.091 m2Smin= 0.0035 m/m
Pendiente máxima
Amax= 0.016 m2
Pmax= 0.478 m2
Rh= 0.033 m2Smax= 0.2494 m/m
Pendiente normal del canal:
So= 0.0044 m/m Ok Cumple!!!
Hf= 0.961 m
Numero de Froude
V= 0.762 m/s
A= 0.061 m2
T= 0.40 m2
Fr= 0.6212 Régimen Subcrítico
Perdida de carga
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
Cálculo del Borde libre:
BL = 0.08 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.40 m
h = 0.30 m
e = 0.2 m
Dimensionamiento Final:
0.15m
0.3m
0.15 m
0.4 m
CANAL 19
Cota Inicial= 2156.38 [m.s.n.m.] 200.00
Cota final= 2152.980 [m.s.n.m.] 500
L= 300.00 [m]
Qd = 0.042 m3/s
So = 0.01133 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.282 m. Asumimos Constructivamente b = 0.40 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.11 m
Datos de iniciales
Prog.inicial=2+
Prog.Final=2+
[Concreto ]
𝐵𝐿 =𝑦
2
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
Cota inicial
Cota Final
solera
So
L
?h
0.007 = 0.007 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.042 m2
Perímetro:
P= 0.612 m
Radio Hidráulico:
Rh= 0.069 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.9969 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.060 m2
Pmin= 0.702 m2
Rh= 0.086 m2Smin= 0.0037 m/m
Pendiente máxima
Amax= 0.014 m2
Pmax= 0.471 m2
Rh= 0.030 m2
Smax= 0.2794 m/m
Pendiente normal del canal:
So= 0.0101 m/m Ok Cumple!!!
Hf= 3.026 m
Numero de Froude
V= 0.997 m/s
A= 0.042 m2
T= 0.40 m2
Fr= 0.9772 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.05 m
Se asumirá un borde libre constructivo de: BL = 0.19 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
Perdida de carga
𝐵𝐿 =𝑦
2
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b = 0.40 m
h = 0.30 m
e = 0.2 m
Dimensionamiento Final:
0.19m
0.3m
0.11 m
0.4 m
CANAL 20
Cota Inicial= 2152.98 [m.s.n.m.] 500.00
Cota final= 2152.750 [m.s.n.m.] 540
L= 40.00 [m]
Qd = 0.023 m3/s
So = 0.00575 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.256 m. Asumimos Constructivamente b = 0.40 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.08 m
0.005 = 0.005 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.032 m2
Perímetro:
Datos de iniciales
Prog.inicial=2+
Prog.Final=2+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
Cota inicial
Cota Final
solera
So
L
?h
P= 0.560 m
Radio Hidráulico:
Rh= 0.057 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Velocidad en la sección
V= 0.7313 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.033 m2
Pmin= 0.567 m2
Rh= 0.059 m2
Smin= 0.0062 m/m
Pendiente máxima
Amax= 0.008 m2
Pmax= 0.439 m2
Rh= 0.018 m2
Smax= 0.5610 m/m
Pendiente normal del canal:
So= 0.0070 m/m Ok Cumple!!!
Hf= 0.281 m
Numero de Froude
V= 0.731 m/s
A= 0.032 m2
T= 0.40 m2
Fr= 0.8254 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.04 m
Se asumirá un borde libre constructivo de: BL = 0.22 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.40 m
h = 0.30 m
e = 0.2 m
Dimensionamiento Final:
Perdida de carga
𝐵𝐿 =𝑦
2
𝑃 𝑏 + 2 𝑦
𝑅ℎ = 𝐴 𝑃
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
0.22m
0.3m
0.08 m
0.4 m
CANAL 21
Cota Inicial= 2152.75 [m.s.n.m.] 540.00
Cota final= 2151.000 [m.s.n.m.] 750
L= 210.00 [m]
Qd = 0.012 m3/s
So = 0.00833 [m/m]
n = 0.017
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.183 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.07 m
0.002 = 0.002 Ok!!! Se Iguala
Calculo de propiedades geometricas e hidráulicas de la sección
Area:
A= 0.015 m2
Perímetro:
P= 0.345 m
Radio Hidráulico:
Rh= 0.042 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.7 m/s
Datos de iniciales
Prog.inicial=2+
Prog.Final=2+
[Concreto ]
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
Cota inicial
Cota Final
solera
So
L
?h
Velocidad en la sección
V= 0.7915 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.016 m2
Pmin= 0.364 m2
Rh= 0.045 m2
Smin= 0.0088 m/m
Pendiente máxima
Amax= 0.004 m2
Pmax= 0.238 m2
Rh= 0.016 m2
Smax= 0.6406 m/m
Pendiente normal del canal:
So= 0.0124 m/m Ok Cumple!!!
Hf= 2.598 m
Numero de Froude
V= 0.792 m/s
A= 0.015 m2
T= 0.20 m2
Fr= 0.9376 Régimen Subcrítico
Cálculo del Borde libre:
BL = 0.04 m
Se asumirá un borde libre constructivo de: BL = 0.18 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.60 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.25 m
e = 0.2 m
Dimensionamiento Final:
0.18m
0.25m
0.07 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐹𝑟 =𝑉
𝑔 ∗𝐴𝑇
b=
e= 0.20m
=h
e=0.20m
Y=
BL=
e= 0.20m
RAPIDA 1
datos.
2185.880 32.44
2184.07 86.23
Q= 0.1356 m3/s
∆H= 1.81 m [Desnivel de la Rapida]
Lh= 53.79 m
L= 53.82 m [Longitrud de la Rapida]
canal de entrada canal de entrada
Yn1= 0.24 [m] Yn2= 0.29 [m]
b= 0.60 m b= 0.60 m
A= 0.15 [m2] A= 0.17 [m2]
T= 0.60 [m] T= 0.60 [m]
P= 1.08 [m] P= 1.18 [m]
R= 0.13 [m] R= 0.15 [m]
V= 0.93 [m/s] V= 0.78 [m/s]
Fr= 0.61 subcritico Fr= 0.46 subcritico
hv= 0.044 m hv= 0.031 m
E= 0.286 m.kg/kg E= 0.321 m.kg/kg
Ym= 0.242 [m] Ym= 0.291 [m]
2.- Seccion de control
tirante normal Yn1= 0.242 [m]
cota entrada (m.s.n.m.): Prog.inicial=0+0
cota salida (m.s.n.m.): Prog.Final=0+0
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
𝑉2
Carga de Velocidad 0.044 [m]
Energia especifica: 0.286 [m*kg/kg]
Yc = 0.19 m.
0.519 m
0.191 m
B1 = 0.519 m.
se Asume 0.520 m.
1.369 m/s
3.- Calculo de la longitud de transición:
se asume
0.10 Lt=0.60 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.191 m
Bc= 0.520 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 5.382 0.034 0.191 1.37 0.286 0.467 0.010
1 5.38 5.382 0.034 0.125 2.09 0.348 0.529 0.034 0.022 0.120 0.467
2 10.76 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.183 0.529
3 16.15 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
4 21.53 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
5 26.91 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
6 32.29 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
7 37.67 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
8 43.06 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
9 48.44 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
10 53.82 5.382 0.034 0.125 2.08 0.346 0.527 0.034 0.034 0.181 0.527
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
Calculo de Yn en la rapida:
Tirante real. Y: 0.125 m
Tirante normal. Yn: 0.189 m
Tirante critico. Yc: 0.191 m
Si Yn = 0.19 m Zona 3
0.013 = 0.013 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.191 0.61 0.80 Se asume.
0.125 0.61 0.73 H = 0.74 m. a partir del 1er tramo.
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
0.125 0.61 0.74
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.520 m [Base del Canal]
Yn2 = 0.291 m [Tirante del Canal de salida]
Y1 = 0.125 m [Tirante en el que las Energias se igualan]
V1= 2.08 m/s
1.87
YVBL 0371,061,0
𝐹𝑟1 =𝑉1
𝑔𝑌1=
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
Y2= 0.28 m
longitud del colchon:
L= 0.75 m
L= 5.00 m
e= 0.03 m
e= 0.10 m
RAPIDA 2
datos.
2183.960 112.81
2181.00 190.00
Q= 0.1323 m3/s
∆H= 2.96 m [Desnivel de la Rapida]
Lh= 77.19 m
L= 77.25 m [Longitrud de la Rapida]
canal de entrada canal de entrada
cota salida (m.s.n.m.): Prog.Final=0+
cota entrada (m.s.n.m.): Prog.inicial=0+
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
Yn1= 0.19 [m] Yn2= 0.25 [m]
b= 0.60 m b= 0.60 m
A= 0.12 [m2] A= 0.15 [m2]
T= 0.60 [m] T= 0.60 [m]
P= 0.99 [m] P= 1.10 [m]
R= 0.12 [m] R= 0.14 [m]
V= 1.13 [m/s] V= 0.88 [m/s]
Fr= 0.82 subcritico Fr= 0.56 subcritico
hv= 0.066 m hv= 0.039 m
E= 0.260 m.kg/kg E= 0.291 m.kg/kg
Ym= 0.194 [m] Ym= 0.251 [m]
2.- Seccion de control
tirante normal Yn1= 0.194 [m]
Carga de Velocidad 0.066 [m]
Energia especifica: 0.260 [m*kg/kg]
Yc = 0.17 m.
0.586 m
0.173 m
B1 = 0.586 m.
se Asume 0.590 m.
1.304 m/s
3.- Calculo de la longitud de transición:
se asume
0.02 Lt=0.52 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.173 m
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
Bc= 0.590 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 7.725 0.038 0.173 1.29 0.259 0.55 0.009
1 7.72 7.725 0.038 0.103 2.17 0.343 0.64 0.042 0.026 0.197 0.54
2 15.45 7.725 0.038 0.109 2.06 0.325 0.62 0.036 0.039 0.300 0.63
3 23.17 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.280 0.61
4 30.90 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
5 38.62 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
6 46.35 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
7 54.07 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
8 61.80 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
9 69.52 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
10 77.25 7.725 0.038 0.108 2.07 0.327 0.62 0.036 0.036 0.282 0.61
Calculo de Yn en la rapida:
Tirante real. Y: 0.108 m
Tirante normal. Yn: 0.167 m
Tirante critico. Yc: 0.173 m
Si Yn = 0.17 m Zona 3
0.012 = 0.011 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.173 0.61 0.78 Se asume.
0.103 0.61 0.71 H = 0.72 m. a partir del 1er tramo.
0.109 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
2
3
2
R
nVSE
YVBL 0371,061,0
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.590 m [Base del Canal]
Yn2 = 0.251 m [Tirante del Canal de salida]
Y1 = 0.108 m [Tirante en el que las Energias se igualan]
V1= 2.07 m/s
2.01
Y2= 0.26 m
longitud del colchon:
L= 0.75 m
L= 5.00 m
e= 0.05 m
e= 0.10 m
RAPIDA 3
datos.
2180.540 260.00
2178.96 328.36
Q= 0.1275 m3/s
∆H= 1.58 m [Desnivel de la Rapida]
Lh= 68.36 m
cota entrada (m.s.n.m.): Prog.inicial=0+
cota salida (m.s.n.m.): Prog.Final=0+
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑉1
𝑔𝑌1=
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
L= 68.38 m [Longitrud de la Rapida]
canal de entrada canal de entrada
Yn1= 0.21 [m] Yn2= 0.26 [m]
b= 0.45 m b= 0.55 m
A= 0.10 [m2] A= 0.14 [m2]
T= 0.45 [m] T= 0.55 [m]
P= 0.87 [m] P= 1.07 [m]
R= 0.11 [m] R= 0.13 [m]
V= 1.34 [m/s] V= 0.90 [m/s]
Fr= 0.93 subcritico Fr= 0.56 subcritico
hv= 0.092 m hv= 0.041 m
E= 0.303 m.kg/kg E= 0.300 m.kg/kg
Ym= 0.211 [m] Ym= 0.259 [m]
2.- Seccion de control
tirante normal Yn1= 0.211 [m]
Carga de Velocidad 0.092 [m]
Energia especifica: 0.303 [m*kg/kg]
Yc = 0.20 m.
0.449 m
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
3 𝑄2
Y c
0.202 m
B1 = 0.449 m.
se Asume 0.450 m.
1.408 m/s
3.- Calculo de la longitud de transición:
se asume
0.00 Lt=0.50 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.202 m
Bc= 0.450 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 6.838 0.023 0.202 1.40 0.302 0.460 0.011
1 6.84 6.838 0.038 0.15 1.90 0.333 0.595 0.026 0.019 0.128 0.461
2 13.68 6.838 0.038 0.13 2.19 0.374 0.636 0.039 0.032 0.221 0.595
3 20.51 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.039 0.264 0.636
4 27.35 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
5 34.19 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
6 41.03 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
7 47.86 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
8 54.70 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
9 61.54 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
10 68.38 6.838 0.038 0.13 2.18 0.372 0.635 0.038 0.038 0.262 0.635
Calculo de Yn en la rapida:
Tirante real. Y: 0.130 m
Tirante normal. Yn: 0.200 m
Tirante critico. Yc: 0.202 m
Si Yn = 0.20 m Zona 3
0.012 = 0.014 Clasificacion: S
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.202 0.61 0.81 Se asume.
0.149 0.61 0.76 H = 0.76 m. a partir del 1er tramo.
0.129 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
0.130 0.61 0.74
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.450 m [Base del Canal]
Yn2 = 0.259 m [Tirante del Canal de salida]
Y1 = 0.130 m [Tirante en el que las Energias se igualan]
V1= 2.18 m/s
1.93
Y2= 0.30 m
longitud del colchon:
YVBL 0371,061,0
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑉1
𝑔𝑌1=
L= 0.83 m
L= 5.00 m
e= 0.08 m
e= 0.10 m
RAPIDA 4
datos.
2178.790 378.78
2170.14 566.97
Q= 0.1216 m3/s
∆H= 8.65 m [Desnivel de la Rapida]
Lh= 188.19 m
L= 188.39 m [Longitrud de la Rapida]
canal de entrada canal de entrada
Yn1= 0.26 [m] Yn2= 0.23 [m]
b= 0.55 m b= 0.50 m
A= 0.14 [m2] A= 0.11 [m2]
T= 0.55 [m] T= 0.50 [m]
P= 1.07 [m] P= 0.95 [m]
R= 0.13 [m] R= 0.12 [m]
V= 0.86 [m/s] V= 1.08 [m/s]
cota salida (m.s.n.m.): Prog.Final=0+
cota entrada (m.s.n.m.): Prog.inicial=0+
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
Fr= 0.54 subcritico Fr= 0.73 subcritico
hv= 0.037 m hv= 0.059 m
E= 0.296 m.kg/kg E= 0.285 m.kg/kg
Ym= 0.259 [m] Ym= 0.225 [m]
2.- Seccion de control
tirante normal Yn1= 0.259 [m]
Carga de Velocidad 0.037 [m]
Energia especifica: 0.296 [m*kg/kg]
Yc = 0.20 m.
0.443 m
0.197 m
B1 = 0.443 m.
se Asume 0.450 m.
1.391 m/s
3.- Calculo de la longitud de transición:
se asume
0.13 Lt=0.63 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.197 m
Bc= 0.450 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 18.839 0.046 0.197 1.37 0.293 1.159 0.011
1 18.84 18.839 0.046 0.105 2.58 0.444 1.310 0.065 0.038 0.715 1.159
2 37.68 18.839 0.046 0.128 2.11 0.355 1.221 0.036 0.051 0.955 1.310
3 56.52 18.839 0.046 0.114 2.37 0.400 1.266 0.051 0.044 0.820 1.221
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
4 75.36 18.839 0.046 0.120 2.25 0.378 1.244 0.044 0.047 0.889 1.267
5 94.19 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.045 0.855 1.244
6 113.03 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.047 0.888 1.277
7 131.87 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.047 0.888 1.277
8 150.71 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.047 0.888 1.277
9 169.55 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.047 0.888 1.277
10 188.39 18.839 0.046 0.117 2.31 0.389 1.255 0.047 0.047 0.888 1.277
Calculo de Yn en la rapida:
Tirante real. Y: 0.117 m
Tirante normal. Yn: 0.185 m
Tirante critico. Yc: 0.197 m
Si Yn = 0.18 m Zona 3
0.010 = 0.010 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.197 0.61 0.81 Se asume.
0.105 0.61 0.71 H = 0.72 m. a partir del 1er tramo.
0.128 0.61 0.74
0.114 0.61 0.72
0.120 0.61 0.73
0.117 0.61 0.73
0.117 0.61 0.73
0.117 0.61 0.73
0.117 0.61 0.73
0.117 0.61 0.73
0.117 0.61 0.73
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.450 m [Base del Canal]
YVBL 0371,061,0
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
Yn2 = 0.225 m [Tirante del Canal de salida]
Y1 = 0.117 m [Tirante en el que las Energias se igualan]
V1= 2.31 m/s
2.16
Y2= 0.30 m
longitud del colchon:
L= 0.93 m
L= 5.00 m
e= 0.12 m
e= 0.20 m
RAPIDA 5
datos.
2169.600 692.44
2167.55 761.55
Q= 0.1185 m3/s
∆H= 2.05 m [Desnivel de la Rapida]
Lh= 69.11 m
L= 69.14 m [Longitrud de la Rapida]
cota entrada (m.s.n.m.): Prog.inicial=0+
cota salida (m.s.n.m.): Prog.Final=0+
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑉1
𝑔𝑌1=
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
canal de entrada canal de entrada
Yn1= 0.24 [m] Yn2= 0.25 [m]
b= 0.55 m b= 0.50 m
A= 0.13 [m2] A= 0.12 [m2]
T= 0.55 [m] T= 0.50 [m]
P= 1.02 [m] P= 1.00 [m]
R= 0.13 [m] R= 0.12 [m]
V= 0.91 [m/s] V= 0.95 [m/s]
Fr= 0.59 subcritico Fr= 0.61 subcritico
hv= 0.042 m hv= 0.046 m
E= 0.279 m.kg/kg E= 0.295 m.kg/kg
Ym= 0.237 [m] Ym= 0.249 [m]
2.- Seccion de control
tirante normal Yn1= 0.237 [m]
Carga de Velocidad 0.042 [m]
Energia especifica: 0.279 [m*kg/kg]
Yc = 0.19 m.
0.471 m
0.186 m
B1 = 0.471 m.
se Asume 0.480 m.
1.352 m/s
3.- Calculo de la longitud de transición:
se asume
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐵1 − 𝐵2
0.10 Lt=0.60 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.186 m
Bc= 0.480 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 6.914 0.030 0.186 1.33 0.276 0.481 0.010
1 6.91 6.914 0.030 0.122 2.02 0.330 0.535 0.034 0.022 0.151 0.481
2 13.83 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.032 0.218 0.536
3 20.74 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.523
4 27.66 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
5 34.57 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
6 41.48 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
7 48.40 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
8 55.31 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
9 62.23 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
10 69.14 6.914 0.030 0.128 1.93 0.318 0.523 0.030 0.030 0.205 0.524
Calculo de Yn en la rapida:
Tirante real. Y: 0.128 m
Tirante normal. Yn: 0.185 m
Tirante critico. Yc: 0.186 m
Si Yn = 0.18 m Zona 3
0.012 = 0.012 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.186 0.61 0.80 Se asume.
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
YVBL 0371,061,0
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
0.122 0.61 0.73 H = 0.74 m. a partir del 1er tramo.
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
0.128 0.61 0.74
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.480 m [Base del Canal]
Yn2 = 0.249 m [Tirante del Canal de salida]
Y1 = 0.128 m [Tirante en el que las Energias se igualan]
V1= 1.93 m/s
1.73
Y2= 0.25 m
longitud del colchon:
L= 0.63 m
L= 5.00 m
e= 0.04 m
e= 0.10 m
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑉1
𝑔𝑌1=
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
RAPIDA 6
datos.
2167.000 890
2161.11 940.76
Q= 0.1185 m3/s
∆H= 5.89 m [Desnivel de la Rapida]
Lh= 50.76 m
L= 51.10 m [Longitrud de la Rapida]
canal de entrada canal de entrada
Yn1= 0.25 [m] Yn2= 0.24 [m]
b= 0.50 m b= 0.50 m
A= 0.12 [m2] A= 0.12 [m2]
T= 0.50 [m] T= 0.50 [m]
P= 1.00 [m] P= 0.99 [m]
R= 0.12 [m] R= 0.12 [m]
V= 0.95 [m/s] V= 0.98 [m/s]
Fr= 0.61 subcritico Fr= 0.63 subcritico
hv= 0.046 m hv= 0.049 m
E= 0.295 m.kg/kg E= 0.291 m.kg/kg
Ym= 0.249 [m] Ym= 0.243 [m]
2.- Seccion de control
tirante normal Yn1= 0.249 [m]
cota entrada (m.s.n.m.): Prog.inicial=0+
cota salida (m.s.n.m.): Prog.Final=0+
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
Carga de Velocidad 0.046 [m]
Energia especifica: 0.295 [m*kg/kg]
Yc = 0.20 m.
0.433 m
0.197 m
B1 = 0.433 m.
se Asume 0.450 m.
1.389 m/s
3.- Calculo de la longitud de transición:
se asume
0.08 Lt=0.58 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
yc= 0.197 m
Bc= 0.450 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 5.110 0.116 0.197 1.34 0.288 0.881 0.010
1 5.11 5.110 0.116 0.086 3.08 0.569 1.162 0.112 0.061 0.312 0.881
2 10.22 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.114 0.582 1.162
3 15.33 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
4 20.44 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
5 25.55 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
6 30.66 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
7 35.77 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
8 40.88 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
9 45.99 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
10 51.10 5.110 0.116 0.084 3.12 0.580 1.173 0.116 0.116 0.593 1.173
Calculo de Yn en la rapida:
Tirante real. Y: 0.084 m
Tirante normal. Yn: 0.132 m
Tirante critico. Yc: 0.197 m
Si Yn = 0.13 m Zona 3
0.006 = 0.006 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.197 0.61 0.81 Se asume.
0.086 0.61 0.70 H = 0.7 m. a partir del 1er tramo.
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
0.084 0.61 0.69
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.450 m [Base del Canal]
Yn2 = 0.243 m [Tirante del Canal de salida]
Y1 = 0.084 m [Tirante en el que las Energias se igualan]
V1= 3.12 m/s
3.43
YVBL 0371,061,0
𝐹𝑟1 =𝑉1
𝑔𝑌=
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
Y2= 0.37 m
longitud del colchon:
L= 1.42 m
L= 6.00 m
e= 0.18 m
e= 0.20 m
RAPIDA 7
datos.
2159.430 530.00
2156.83 645.35
Q= 0.0672 m3/s
∆H= 2.60 m [Desnivel de la Rapida]
Lh= 115.35 m
L= 115.38 m [Longitrud de la Rapida]
cota entrada (m.s.n.m.): Prog.inicial=1+
cota salida (m.s.n.m.): Prog.Final=1+
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑔𝑌1
=
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
canal de entrada canal de entrada
Yn1= 0.19 [m] Yn2= 0.19 [m]
b= 0.50 m b= 0.40 m
A= 0.09 [m2] A= 0.08 [m2]
T= 0.50 [m] T= 0.40 [m]
P= 0.87 [m] P= 0.79 [m]
R= 0.11 [m] R= 0.10 [m]
V= 0.72 [m/s] V= 0.86 [m/s]
Fr= 0.53 subcritico Fr= 0.62 subcritico
hv= 0.026 m hv= 0.038 m
E= 0.213 m.kg/kg E= 0.233 m.kg/kg
Ym= 0.187 [m] Ym= 0.195 [m]
2.- Seccion de control
tirante normal Yn1= 0.187 [m]
Carga de Velocidad 0.026 [m]
Energia especifica: 0.213 [m*kg/kg]
Yc = 0.14 m.
0.400 m
0.142 m
B1 = 0.400 m.
se Asume 0.400 m.
1.181 m/s
3.- Calculo de la longitud de transición:
se asume
0.12 Lt=0.62 m
4.-Calculo de los tirantes en la rápida (curva de remanso): Metodo de los tramos fijos: Flujo Gradualmente variado.
Ecuacion General de Tramos Fijos
Yn1Yc
Y1
Y2 Yn2
0c 1
2
bn1 Bc bn2
longitud de la rapida
h
CANAL DEENTRADA
CANAL DE
SALIDA
CANAL DELA RAPIDA
Seccionde control
.
Longitud de transiciónLongitud de transición
ℎ𝑣 =𝑉2
2𝑔=
𝐸1 = 𝑌𝑛1+ℎ𝑣 =
𝑏𝑐 =27𝑄2
8𝐸𝑚𝑖𝑛3 𝑔
=
𝑌𝑐 =3 𝑄2
𝑏2 ∗ 𝑔=
𝑉𝑐 = 𝑌𝑐 ∗ 𝑔 =
Y c
𝐿 =𝐵1 − 𝐵2
2 ∗ 𝑡𝑎𝑛22.5=
XSEEXSo E 21 2
21 SESESE
2
3
2
R
nVSE
yc= 0.142 m
Bc= 0.400 m
n= 0.017
TRAMO X ΔX So y V E E+So ΔX SE SEm SEm ΔX E+SEmed ΔX
0 0 11.538 0.023 0.142 1.18 0.213 0.473 0.011
1 11.54 11.538 0.023 0.101 1.66 0.241 0.501 0.029 0.020 0.232 0.473
2 23.08 11.538 0.023 0.117 1.44 0.222 0.482 0.019 0.024 0.279 0.501
3 34.61 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.022 0.251 0.483
4 46.15 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
5 57.69 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
6 69.23 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
7 80.77 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
8 92.30 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
9 103.84 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
10 115.38 11.538 0.023 0.108 1.56 0.231 0.491 0.024 0.024 0.279 0.510
Calculo de Yn en la rapida:
Tirante real. Y: 0.108 m
Tirante normal. Yn: 0.132 m
Tirante critico. Yc: 0.142 m
Si Yn = 0.13 m Zona 3
0.006 = 0.008 Clasificacion: S
Tipo de Curva: S3
5.-Cálculo del Borde Libre
Y BL H
0.142 0.61 0.75 Se asume.
0.101 0.61 0.71 H = 0.72 m. a partir del 1er tramo.
0.117 0.61 0.73
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
XSEEXSo E 21
2
3
2
R
nVSE
YVBL 0371,061,0
𝑏 ∗ 𝑌𝑛5
𝑏 + 2 ∗ 𝑌𝑛2=
𝑄 ∗ 𝑛
𝑆𝑜0.5
3
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
0.108 0.61 0.72
6.-CALCULO DE LA LONGITUD Y LA PROFUNDIDAD DEL COLCHON DISIPADOR :
Flujo rapidamente Variado.
B = 0.400 m [Base del Canal]
Yn2 = 0.195 m [Tirante del Canal de salida]
Y1 = 0.108 m [Tirante en el que las Energias se igualan]
V1= 1.56 m/s
1.51
Y2= 0.18 m
longitud del colchon:
L= 0.38 m
L= 5.00 m
e= 0.02 m
e= 0.10 m
𝑌2 =𝑌12
1 + 8𝐹𝑟12 − 1
𝐹𝑟1 =𝑉1
𝑔𝑌1=
𝐿 = 5(𝑌2 − 𝑌1)
𝑒 = 1.15 ∗ 𝑌2 − 𝑌𝑛2
COMPUERTAS.
Compuerta 1
Q= 0.14 m^3/s
b= 0.60 m
cd= 0.60
a= 0.1 m
h= 0.90 m
Compuerta 2
Q= 0.13 m^3/s
b= 0.60 m
cd= 0.60
a= 0.1 m
h= 0.88 m
Compuerta 3
Q= 0.13 m^3/s
b= 0.45 m
cd= 0.60
a= 0.1 m
h= 1.04 m
Compuerta 4
Q= 0.12 m^3/s
b= 0.55 m
cd= 0.60
a= 0.1 m
h= 0.88 m
𝑄 = 𝐶𝑑 ∗ 𝑏 ∗ 𝑎 ∗ 2 ∗ 𝑔 ∗ ℎ
L
Compuerta 5
Q= 0.12 m^3/s
b= 0.55 m
cd= 0.60
a= 0.1 m
h= 0.87 m
Compuerta 6
Q= 0.12 m^3/s
b= 0.55 m
cd= 0.60
a= 0.1 m
h= 0.85 m
Compuerta 7
Q= 0.09 m^3/s
b= 0.50 m
cd= 0.60
a= 0.1 m
h= 0.77 m
Compuerta 8
Q= 0.067 m^3/s
b= 0.50 m
cd= 0.60
a= 0.1 m
h= 0.63 m
Compuerta 9
Q= 0.063 m^3/s
b= 0.50 m
cd= 0.60
a= 0.1 m
h= 0.61 m
Compuerta 10
Q= 0.059 m^3/s
b= 0.40 m
cd= 0.60
a= 0.1 m
h= 0.67 m
Compuerta 11
Q= 0.047 m^3/s
b= 0.40 m
cd= 0.60
a= 0.1 m
h= 0.58 m
Compuerta 12
Q= 0.042 m^3/s
b= 0.40 m
cd= 0.60
a= 0.1 m
h= 0.54 m
Compuerta 13
Q= 0.023 m^3/s
b= 0.40 m
cd= 0.60
a= 0.1 m
h= 0.36 m
Compuerta 14
Q= 0.012 m^3/s
b= 0.20 m
cd= 0.60
a= 0.1 m
h= 0.36 m
Cota Inicial= 2184.04 [m.s.n.m.] 0.00
Cota final= 2178.720 [m.s.n.m.] 108
L= 108.00 [m] Cota inicial solera Canal
Qd = 0.003 m3/s S
So = 0.04929 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.084 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.02 m
0.0004 = 0.0003 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.005 m2
Perímetro:
P= 0.249 m
Radio Hidráulico:
Rh= 0.020 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.672 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.006 m2
Pmin= 0.255 m2
Rh= 0.022 m2 Smin= 0.0193 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.001 m2
Pmax= 0.211 m2
Rh= 0.005 m2 Smin= 3.2071 m/m
Pendiente normal del canal:
So= 0.0274 m/m Ok Cumple!!!
Hf= 2.957 m
Cálculo del Borde libre:
BL = 0.01 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.17 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.17m
Yn =0.02 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2182.06 [m.s.n.m.] 0.00
Cota final= 2174.747 [m.s.n.m.] 181.07
L= 181.07 [m] Cota inicial solera Canal
Qd = 0.005 m3/s S
So = 0.04038 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.100 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.02 m
0.0004 = 0.0004 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.005 m2
Perímetro:
P= 0.249 m
Radio Hidráulico:
Rh= 0.020 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.961 m/s Ok Cumple!!!
Pendiente minima
Amin= 0.008 m2
Pmin= 0.279 m2
Rh= 0.028 m2 Smin= 0.0135 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.002 m2
Pmax= 0.216 m2
Rh= 0.007 m2 Smin= 2.0524 m/m
Pendiente normal del canal:
So= 0.0559 m/m Ok Cumple!!!
Hf= 10.124 m
Cálculo del Borde libre:
BL = 0.01 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.17 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.17m
Yn =0.02 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2178.83 [m.s.n.m.] 0.00
Cota final= 2173.628 [m.s.n.m.] 209.11
L= 209.11 [m] Cota inicial solera Canal
Qd = 0.006 m3/s S
So = 0.02488 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.119 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.02 m
0.0004 = 0.0007 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.005 m2
Perímetro:
P= 0.249 m
Radio Hidráulico:
Rh= 0.020 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.200 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.010 m2
Pmin= 0.299 m2
Rh= 0.033 m2 Smin= 0.0110 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.002 m2
Pmax= 0.220 m2
Rh= 0.009 m2 Smin= 1.5637 m/m
Pendiente normal del canal:
So= 0.0872 m/m Ok Cumple!!!
Hf= 18.224 m
Cálculo del Borde libre:
BL = 0.01 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.17 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.17m
Yn =0.02 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2169.93 [m.s.n.m.] 0.00
Cota final= 2164.000 [m.s.n.m.] 202.66
L= 202.66 [m] Cota inicial solera Canal
Qd = 0.003 m3/s S
So = 0.02928 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.091 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.02 m
0.0004 = 0.0003 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.005 m2
Perímetro:
P= 0.249 m
Radio Hidráulico:
Rh= 0.020 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.635 m/s Ok Cumple!!!
Pendiente minima
Amín= 0.005 m2
Pmin= 0.252 m2
Rh= 0.021 m2 Smin= 0.0205 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.001 m2
Pmax= 0.210 m2
Rh= 0.005 m2 Smin= 3.4466 m/m
Pendiente normal del canal:
So= 0.0244 m/m Ok Cumple!!!
Hf= 4.951 m
Cálculo del Borde libre:
BL = 0.01 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.17 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.17m
Yn =0.02 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2161.01 [m.s.n.m.] 0.00
Cota final= 2159.870 [m.s.n.m.] 42.03
L= 42.03 [m] Cota inicial solera Canal
Qd = 0.003 m3/s S
So = 0.02719 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.091 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.02 m
0.0004 = 0.0003 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.005 m2
Perímetro:
P= 0.249 m
Radio Hidráulico:
Rh= 0.020 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.609 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.005 m2
Pmin= 0.250 m2
Rh= 0.020 m2 Smin= 0.0215 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.001 m2
Pmax= 0.210 m2
Rh= 0.005 m2 Smin= 3.6374 m/m
Pendiente normal del canal:
So= 0.0224 m/m Ok Cumple!!!
Hf= 0.943 m
Cálculo del Borde libre:
BL = 0.01 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.17 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.17m
Yn =0.02 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2160.64 [m.s.n.m.] 0.00
Cota final= 2140.316 [m.s.n.m.] 625.97
L= 625.97 [m] Cota inicial solera Canal
Qd = 0.025 m3/s S
So = 0.03247 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.194 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.10 m
0.0026 = 0.0025 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.020 m2
Perímetro:
P= 0.396 m
Radio Hidráulico:
Rh= 0.050 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.273 m/s Ok Cumple!!!
Pendiente minima
Amin= 0.042 m2
Pmin= 0.616 m2
Rh= 0.068 m2 Smin= 0.0042 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.008 m2
Pmax= 0.283 m2
Rh= 0.029 m2 Smin= 0.3214 m/m
Pendiente normal del canal:
So= 0.0289 m/m Ok Cumple!!!
Hf= 18.080 m
Cálculo del Borde libre:
BL = 0.05 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.25 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.25m
Yn =0.1 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2159.50 [m.s.n.m.] 0.00
Cota final= 2126.306 [m.s.n.m.] 834.26
L= 834.26 [m] Cota inicial solera Canal
Qd = 0.023 m3/s S
So = 0.03979 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.182 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.10 m
0.0026 = 0.0021 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.020 m2
Perímetro:
P= 0.396 m
Radio Hidráulico:
Rh= 0.050 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.188 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.039 m2
Pmin= 0.588 m2
Rh= 0.066 m2 Smin= 0.0044 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.008 m2
Pmax= 0.278 m2
Rh= 0.028 m2 Smin= 0.3434 m/m
Pendiente normal del canal:
So= 0.0251 m/m Ok Cumple!!!
Hf= 20.966 m
Cálculo del Borde libre:
BL = 0.05 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.25 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.25m
Yn =0.1 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2156.67 [m.s.n.m.] 0.00
Cota final= 2146.000 [m.s.n.m.] 212.01
L= 212.01 [m] Cota inicial solera Canal
Qd = 0.005 m3/s S
So = 0.05034 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.094 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.03 m
0.0006 = 0.0004 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.007 m2
Perímetro:
P= 0.265 m
Radio Hidráulico:
Rh= 0.025 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.697 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.008 m2
Pmin= 0.276 m2
Rh= 0.028 m2 Smin= 0.0140 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.002 m2
Pmax= 0.215 m2
Rh= 0.007 m2 Smin= 2.1543 m/m
Pendiente normal del canal:
So= 0.0220 m/m Ok Cumple!!!
Hf= 4.657 m
Cálculo del Borde libre:
BL = 0.02 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.18 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.18m
Yn =0.03 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2156.45 [m.s.n.m.] 0.00
Cota final= 2145.000 [m.s.n.m.] 142.01
L= 142.01 [m] Cota inicial solera Canal
Qd = 0.004 m3/s S
So = 0.08061 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.083 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.03 m
0.0006 = 0.0003 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.007 m2
Perímetro:
P= 0.265 m
Radio Hidráulico:
Rh= 0.025 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.629 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.007 m2
Pmin= 0.269 m2
Rh= 0.026 m2 Smin= 0.0155 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.001 m2
Pmax= 0.214 m2
Rh= 0.006 m2 Smin= 2.4472 m/m
Pendiente normal del canal:
So= 0.0179 m/m Ok Cumple!!!
Hf= 2.541 m
Cálculo del Borde libre:
BL = 0.02 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.18 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.18m
Yn =0.03 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2155.45 [m.s.n.m.] 0.00
Cota final= 2129.000 [m.s.n.m.] 565.88
L= 565.88 [m] Cota inicial solera Canal
Qd = 0.012 m3/s S
So = 0.04673 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.136 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.05 m
0.0010 = 0.0010 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.010 m2
Perímetro:
P= 0.300 m
Radio Hidráulico:
Rh= 0.033 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.176 m/s Ok Cumple!!!
Pendiente minima
Amin= 0.020 m2
Pmin= 0.396 m2
Rh= 0.049 m2 Smin= 0.0064 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.004 m2
Pmax= 0.239 m2
Rh= 0.016 m2 Smin= 0.7007 m/m
Pendiente normal del canal:
So= 0.0417 m/m Ok Cumple!!!
Hf= 23.625 m
Cálculo del Borde libre:
BL = 0.03 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.20 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.2m
Yn =0.05 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2154.38 [m.s.n.m.] 0.00
Cota final= 2144.823 [m.s.n.m.] 200.32
L= 200.32 [m] Cota inicial solera Canal
Qd = 0.004 m3/s S
So = 0.04769 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.095 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.03 m
0.0006 = 0.0004 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.007 m2
Perímetro:
P= 0.265 m
Radio Hidráulico:
Rh= 0.025 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 0.683 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.007 m2
Pmin= 0.274 m2
Rh= 0.027 m2 Smin= 0.0143 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.001 m2
Pmax= 0.215 m2
Rh= 0.007 m2 Smin= 2.2080 m/m
Pendiente normal del canal:
So= 0.0211 m/m Ok Cumple!!!
Hf= 4.228 m
Cálculo del Borde libre:
BL = 0.02 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.18 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.18m
Yn =0.03 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2153.00 [m.s.n.m.] 0.00
Cota final= 2134.000 [m.s.n.m.] 364.65
L= 364.65 [m] Cota inicial solera Canal
Qd = 0.019 m3/s S
So = 0.05210 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.160 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.07 m
0.0017 = 0.0015 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.014 m2
Perímetro:
P= 0.340 m
Radio Hidráulico:
Rh= 0.041 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.353 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.032 m2
Pmin= 0.516 m2
Rh= 0.061 m2 Smin= 0.0048 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.006 m2
Pmax= 0.263 m2
Rh= 0.024 m2 Smin= 0.4212 m/m
Pendiente normal del canal:
So= 0.0417 m/m Ok Cumple!!!
Hf= 15.218 m
Cálculo del Borde libre:
BL = 0.04 m
Se asumirá un borde libre constructivo de: BL = 0.18 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.25 m
e = 0.2 m
Dimensionamiento Final:
BL= 0,18m
h = 0,25m
Yn =0.07 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Cota Inicial= 2152.52 [m.s.n.m.] 0.00
Cota final= 2109.514 [m.s.n.m.] 748.15
L= 748.15 [m] Cota inicial solera Canal
Qd = 0.012 m3/s S
So = 0.05748 [m/m] Cota final
n = 0.018
L
DIMENSIONAMIENTO DE LA SOLERA DEL CANAL:
Máxima Eficiencia Canales Rectangulares
b = 0.132 m. Asumimos Constructivamente b = 0.20 m.
Cálculo del Tirante Normal con la base asumida
Si Yn = 0.05 m
0.0010 = 0.0009 Ok!!! Se Iguala
Calculo de propiedades geométricas e hidráulicas de la sección
Área:
A= 0.010 m2
Perímetro:
P= 0.300 m
Radio Hidráulico:
Rh= 0.033 m
Se debe cumplir los siguientes criterios
Vmax 3 m/s
Vmin 0.6 m/s
Velocidad en la sección
V= 1.183 m/s Ok Cumple!!!
Pendiente mínima
Amín= 0.020 m2
Pmin= 0.397 m2
Rh= 0.050 m2 Smin= 0.0064 m/m
Datos de iniciales
Prog.inicial=0+
Prog.Final=0+
[Hormigón Ciclópeo]
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
2
1
3
21
SoRAn
Q 2Y
b
𝐴 = 𝑏 ∗ 𝑦
𝑃 = 𝑏 + 2 ∗ 𝑦
𝑅ℎ = 𝐴 𝑃
𝑉 = 𝑄/𝐴
𝑆𝑚𝑖𝑛 =𝑉𝑚𝑖𝑛 ∗ 𝑛
𝑅ℎ2/3
2
Pendiente máxima
Amax= 0.004 m2
Pmax= 0.239 m2
Rh= 0.016 m2 Smin= 0.6959 m/m
Pendiente normal del canal:
So= 0.0423 m/m Ok Cumple!!!
Hf= 31.623 m
Cálculo del Borde libre:
BL = 0.03 m
Se asumirá un borde libre constructivo de: BL = 0.15 m
Ancho de corona para caudales menores a 0,50M3/S
C = 0.6 m
Dimensiones Constructivas:
b = 0.20 m
h = 0.20 m
e = 0.2 m
Dimensionamiento Final:
BL= 0.15m
h = 0.2m
Yn =0.05 m
e= 0.2 m
e = 0.2m b = 0.2 m e= 0.2 m
Perdida de carga
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
𝐵𝐿 =𝑦
2
𝑆𝑜 =𝑄 ∗ 𝑛
𝐴 ∗ 𝑅ℎ 2 3
2
𝐻𝑓 = 𝑆𝑜 ∗ 𝐿
𝑆𝑚𝑎𝑥 =𝑉𝑚𝑎𝑥 ∗ 𝑛
𝑅ℎ2/3
2
Prog Caudal (Q) Ancho (b)Profundida
d total (h)
Inicio Fin m3/s m m
Canal principal
Canal 1 0+0.00 0+032.44 0.136 0.60 0.40
Rapida 1 0+032.44 0+86.2 0.136 0.52 0.74
canal 2 0+86.2 0+100.0 0.136 0.60 0.45
canal 3 0+100.0 0+112.8 0.132 0.60 0.35
Rapida 2 0+112.8 0+190.0 0.132 0.59 0.72
Canal 4 0+190.0 0+260.0 0.132 0.60 0.40
Canal 5 0+260.0 0+281.9 0.128 0.45 0.40
Rapida 3 0+281.9 0+328.4 0.128 0.45 0.74
Canal 6 0+328.4 0+360.0 0.128 0.55 0.50
Canal 7 0+360.0 0+378.8 0.122 0.55 0.40
Rapida 4 0+378.8 0+567.0 0.047 0.45 0.72
Canal 8 0+567.0 0+600.0 0.122 0.50 0.40
Canal 9 0+600.0 0+692.4 0.119 0.55 0.40
Rapida 5 0+692.4 0+761.6 0.119 0.48 0.74
Canal 10 0+761.6 0+890.0 0.119 0.50 0.40
Rapida 6 0+890.0 0+940.8 0.119 0.45 0.70
Canal 11 0+940.8 0+980.0 0.119 0.50 0.40
Canal 12 0+980.0 1+070.2 0.116 0.55 0.40
Canal 13 1+070.2 1+530.0 0.091 0.50 0.40
Canal 14 1+530.0 1+550.2 0.067 0.50 0.35
Rapida 7 1+550.2 1+645.4 0.067 0.40 0.72
Canal 15 1+645.4 1+680.0 0.067 0.40 0.35
Canal 16 1+680.0 1+760.0 0.063 0.50 0.30
Canal 17 1+760.0 1+980.0 0.059 0.40 0.35
Canal 18 1+980.0 2+200.0 0.047 0.40 0.30
Canal 19 2+200.0 2+500.0 0.042 0.40 0.30
Canal 20 2+500.0 2+540.0 0.023 0.40 0.30
Canal 21 2+540.0 2+750.0 0.012 0.20 0.25
Canal. Secun.1 0+0.00 0+108.00 0.003 0.20 0.17
Canal. Secun.2 0+0.00 0+181.07 0.005 0.20 0.17
Canal. Secun.3 0+0.00 0+209.11 0.006 0.20 0.17
Canal. Secun.4 0+0.00 0+202.66 0.003 0.20 0.17
Canal. Secun.5 0+0.00 0+42.03 0.003 0.20 0.17
Canal. Secun.6 0+0.00 0+625.97 0.025 0.20 0.25
Canal. Secun.7 0+0.00 0+834.26 0.023 0.20 0.25
Canal. Secun.8 0+0.00 0+212.01 0.005 0.20 0.18
Canal. Secun.9 0+0.00 0+142.01 0.004 0.20 0.18
Canal. Secun.10 0+0.00 0+565.88 0.012 0.20 0.20
Canal. Secun.11 0+0.00 0+200.32 0.004 0.20 0.18
Canal. Secun.12 0+0.00 0+364.65 0.019 0.20 0.25
Canal. Secun.13 0+0.00 0+748.15 0.012 0.20 0.20