MMO 2E1Ad
![Page 2: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/2.jpg)
MMO 2E1AdPresentación
Transporte hasta 2 tributários de 2 Mbps;
Transporte de servicios V.35 / V.36 y Ethernet 10M / 100M;
Exteriorización de alarmas y status por los leds;
Configuración y supervision por notebook;
Gerencia SNMP (a través del Agente SNMP, MMOFLEXAd o AX4E1).
2
![Page 3: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/3.jpg)
MMO 2E1Ad Presentación
PANEL FRONTAL
3
![Page 4: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/4.jpg)
MMO 2E1Ad Presentación
PANEL TRASERO
4
![Page 5: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/5.jpg)
MMO 2E1Ad Interfaces Ópticas
LED
LASER
LASER BIDIRECCIONAL
ST-PC
E2000
SC-APC
CONECTORES:
5
![Page 6: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/6.jpg)
MMO 2E1Ad Interfaces Ópticas
6
![Page 7: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/7.jpg)
MMO 2E1Ad Interfaces Ópticas
7
![Page 8: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/8.jpg)
MMO 2E1Ad Interfaces Eléctricas
2048 kbps ± 50 ppm; Interfaces G.703 75 Ω o 120 Ω;
TX NEGATIVOTX POSITIVO
MALHA RXRX POSITIVO
NCNCMALHA TX
RX NEGATIVO
6.0
6.0
3.0
Dobrar Malha para trás.
Soldar
CONECTOR IEC 169-13 (75Ω) CONECTOR RJ-45 (120Ω)
8
![Page 9: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/9.jpg)
MMO 2E1AdAlimentación
Alimentación Full-Range:
DC: - 48V ± 25% (-36 a -60 VDC)
AC: 90 ~ 250 VAC
Consumo: 7 W
Configuración de los cables de alimentación:
POWER
90-250 VAC36-60 VDC
AC
AC
Terra
POWER
90-250 VAC36-60 VDC
DC
Terra
DC
9
![Page 10: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/10.jpg)
MMO 2E1Adinterfaz de Configuración
Acceso a través del panel frontal (19200bps) o AUX1;
interfaz RS-232 con conector RJ45 para conexion de PC;
Terminal VT-100;
Realización de configuración / pruebas en el enlace;
Actualización del Software (panel frontal).
10
![Page 11: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/11.jpg)
MMO 2E1AdAlarmas Externas / Urgentes
Recolección de hasta 4 Alarmas Externas
Exteriorización de Alarmas Urgentes
Contacto Seco de Relé
Señalización: Alarma Externa 1 → Led LAL Alarma Externa 2 → Led LDL Alarma Externa 3 → Led RDL Alarma Externa 4 → Led BERT
11
![Page 12: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/12.jpg)
MMO 2E1Adinterfaz Nx64
interfaz V.35 (Predeterminado)
Placa multiprotocolo: V.35, V.36, V.28, V.11, X21, RS530 y RS530A
Tasa Nx64 kbps, 1 ≤ N ≤ 32
12
![Page 13: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/13.jpg)
MMO 2E1Adinterfaz Nx64
Conexión Punto a Punto
ETD ETD
Nx64 Nx64
MMO 2E1 Ad MMO 2E1 AdFO
13
![Page 14: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/14.jpg)
MMO 2E1Adinterfaz Nx64
Conexión utilizando Red Pública
ETD
ETD
Nx64
Nx64
G703MMO2E1Ad
FO
RED PUBLICA
V.35
MMM2E1Ad
MMO2E1Ad G703MMO2E1Ad
FOV.35
14
![Page 15: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/15.jpg)
MMO 2E1Adinterfaz Nx64 - Alarmas
TD (103) : Falta de Transmisión de la señal en el ETD RD (104) : Falta de señal en la recepción ETD CTS (106) “Clear to Send”: ECD indica al ETD que puede transmitir datos. DCD (109) “Data carrier Detect”: ECD indica al ETD que está en condiciones Operativas.
15
![Page 16: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/16.jpg)
MMO 2E1AdMódulo LAN
Velocidad de 2 Mbps;
interfaz Ethernet 10baseT / 100BaseT, Half duplex / Full duplex;
Autogestión;
Función de Bridge (Direccion MAC: 1024 direcciones);
Control de Flujo;
Capacidad del buffer: 32 kbytes;
Función de LIN (Link Integrity Notification);
Compatible con las normas IEEE 802.3 y 802.1q.
16
![Page 17: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/17.jpg)
MMO 2E1AdMódulo LAN
LAN
MMO2E1Ad
LAN
MMO2E1AdFO
RED LOCALRED LOCAL
Conexión Punto a Punto
17
![Page 18: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/18.jpg)
MMO 2E1AdMódulo LAN
Conexión utilizando Red Pública
G703MMO2E1Ad
FO
RED LOCAL RED PUBLICA
LAN
MMO2E1Ad
RED LOCAL
MMO2E1Ad G703MMO2E1Ad
LAN FO
18
![Page 19: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/19.jpg)
MMO 2E1AdMódulo LAN - Alarmas
LINK : interfaz Ethernet activa para la red LAN RX : Paquete IP recibido por la interfaz Ethernet TX : Paquete IP transmitido por la interfaz Ethernet 10/100 :
apagado: Ethernet con trafico de 10Mbps verde: Ethernet con trafico de 100Mbps
19
![Page 20: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/20.jpg)
MMO 2E1AdTestes de Loopback – 2Mbps
Test de Loopback Dual
• Ejecutado a través del boton LBK o Laptop.• Verificado a través de los Leds IN1, IN2 y LBK.
E1
Interfaz Óptica E1
MMO2E1Ad MMO2E1Ad
20
![Page 21: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/21.jpg)
MMO 2E1AdPruebas – interfaz V.35
LAL : Loop Analógico Local (interfaz G.703) LDL : Loop Digital Local (interfaz V.35/V.36) RDL : Loop Digital Remoto (interfaz V.35/V.36 remota) BERT: Inyección y análisis de errores para 2M
FOETDLOCAL
ETD REMOTO
MMO2E1 Ad MMO2E1 Ad
V.35/V.36 V.35/V.36G.703
LALLDL RDL
21
![Page 22: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/22.jpg)
MMO 2E1AdPruebas – interfaz V.35
LAL : Loop Analógico Local (interfaz G.703) LDL : Loop Digital Local (interfaz V.35/V.36) RDL : Loop Digital Remoto (interfaz V.35/V.36 remota) BERT: Inyección y análisis de errores para 2M
22
![Page 23: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/23.jpg)
MMO 2E1AdGerencia
Protocolo SSX;
Gerencia SNMP - Agente SNMP, MMOFLEXAd o AX4E1;
Gerencia de Alarmas: Cualquier software de gerenciamiento que utilice el protocolo SNMP. (Indicarse el software SNMPc);
Configuración: Terminal AsGa.
Switch(red ethernet)
Gerencia SNMP
ProtocoloSNMP
Protocolo SNMP
MMO 2E1 Ad
Enlace Óptico
MMO FLEX Ad
Enlace Óptico
GERENTE
MMO 2E1 AdAgente SNMP
MMO 2E1 Ad
MMO 2E1 Ad
Protocolo SSX
Protocolo SSX
Protocolo SSX
23
![Page 24: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/24.jpg)
MMO 2E1AdInterconexión - Gerencia SNMP
Obs.: La puerta frontal puede ser configurada para operar como AUX2.
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2 AUX1 AUX2
AUX1 AUX2
LOCAL A
LOCAL C
LOCAL B
LOCAL D
LOCAL ELOCAL F
A1
A2
C2
C1
B3
B2
B1
A3
LOCAL G
SNMP
Aggggg Pgggg
Agente SNMP - RoteadorAsGa
TXRXRXTXRX
interfazRS232
2
FALHARESET LIGTX LINKRX
interfazDE REDE
OPERAÇÃO
Switch(red Ethernet)
Gggggggg
SNMP
Fibra ópticaCable serialCable UTP
24
![Page 25: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/25.jpg)
MMO 2E1AdCables de Gerencia
Supervisión Local:
Extensión de Gerencia AUX1/AUX1 y AUX1 / AUX2:
25
![Page 26: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/26.jpg)
MMO 2E1AdConfiguración de los Enlaces
Conexión MMO2E1 - MMO2E1
Modem AModem B
26
![Page 27: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/27.jpg)
MMO 2E1AdConfiguración de los Enlaces
Conexión MMOFLEX - MMO2E1
Local A
Local B
Local D
Local C
27
![Page 28: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/28.jpg)
MMO 2E1AdConfiguraciones Iniciales
Configuración de interfaz 75Ω / 120Ω Llaves 1 y 2: Tierra
Llaves 1: ON entrada a tierraOFF entrada abierta
Llave 2: ON salida a tierraOFF: salida abierta
Llave 3 y 4: ImpedanciaON: 75 ΩOFF: 120 Ω
28
![Page 29: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/29.jpg)
MMO 2E1AdInstalación
Desembalaje• Manipule con cuidado la caja• Use herramientas de corte con cautela en la apertura de la cinta.• El paquete soporta pequeñas sacudidas Mecánicas y salpicaduras de agua• Transporte a largas distancias.
Presentación• Equipo• Manual de operación• Cable tripolar• Kit de fijación
29
![Page 30: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/30.jpg)
MMO 2E1AdInstalación
Rack de 40U
30
![Page 31: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/31.jpg)
MMO 2E1AdEjercicios Prácticos
Montaje de la instalación:
Material utilizado:
2 MMO2E1Ad
Fibras ópticas
Cables Coaxiles
E1MMO 2E1 Ad MMO 2E1 Ad
FO E1
Modem A Modem B
Analizadorde 2M
Loop físico
31
![Page 32: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/32.jpg)
MMO 2E1AdEjercicios Prácticos
Programa de instalación:
Verificar a través de los leds en el panel frontal:
Status de la interfaz óptica
Status de las interfaces elétricas
Status del equipo remoto (led REM AL)
E1MMO 2E1 Ad MMO 2E1 Ad
FO E1
Modem A Modem B
Analizadorde 2M
Loop físico
32
![Page 33: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/33.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
A- Status:
Verificar a través de la Terminal AsGa:
• Status de las alarmas
• Status de la configuración
• Dirección a través de la puerta frontal
33
![Page 34: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/34.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
B- Configuraciones del enlace:
Configurar:• Dirección del enlace: 10• Tasa de serie: 4800• Gerencia extendida: habilitar• SIA en caso de loop óptico: habilitar (en el caso de interfaz óptica bidirecional)• Configurar el enlace como 1E1• Configurar el enlace como 2E1
34
![Page 35: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/35.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
C- Configuraciones del modem:
Configurar:
• Tipo de modem remoto: MMO2E1Ad (N64)
• Modem local como A
35
![Page 36: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/36.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
C- Configuraciones del modem:
• Configurar: modem A: Canal 1: G.703 y modem B: Canal 1: G.703
• Configurar modem A como Canal 1: G.703 + Canal 2: G.703 y modem B: Canal 1: G.703 + Canal 2: V.35
• Configurar modem A como Canal 1: G.703 + Canal 2: G.703 y modem B: Canal 1: G.703 + Canal 2: LAN
• Configurar modem A como Canal 1: G.703 + Canal 2: G.703 y modem B: Canal 1: G.703 + Canal 2: Conversor V.35 / G.703
• Configurar: modem A como Canal 1: G.703 + Canal 2: G.703 y modem B: Canal 1: G.703 + Canal 2: G.703
36
![Page 37: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/37.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
D- Módulo N64:
Si existe módulo N64, configurar:
• Tasa digital: 1600 kbps
• JT16: Señalización
• CAS: desactivar
• CRC4: habilitar
• Los canales no utilizados: IDLE
• Fuente del reloj: Modem A: Interna, Modem B: recuperado
• Confirmar las configuraciones a través del Status
37
![Page 38: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/38.jpg)
MMO 2E1AdEjercicios Prácticos
2- Configuración a través de notebook (via software):
E- Módulo LAN (caso utilizado):
Habilitar las placas y colocar la configuración deseada (10/100, half/full, auto).
Utilizando un analisador Ethernet, verificar el tráfico de paquetes.
38
![Page 39: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/39.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
F- Operación: Pruebas de Reset
Realizar:
• Restablecer la gestión(verificar que no haya interrupción de tráfico)
• Restablecimiento del equipo(verificar que hay interrupción de tráfico)
39
![Page 40: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/40.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
F- Operación: Pruebas de Loopback
Realizar:
• Loopback dual en el canal 1 del modem local
Verificar a través del Analizador
Realizar:
• Loopback dual en el canal 2 del modem remoto
Verificar a través del Analizador
Desactivar el loopback a través del reset de comandos
40
![Page 41: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/41.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
F- Operación: Pruebas en la interfaz N64 (si se utilizan)
Realizar:
• Loopback digital local y verificar a través del Analizador
• Loopback analógico y verificar a través del Analizador
• Loopback digital remoto y verificar a través del Analizador
• Pruebas de BERT y Loopback digital remoto. Verificar la prueba a través del led BERT (verde: ok; rojo: falla)
41
![Page 42: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/42.jpg)
MMO 2E1AdEjercicios Prácticos
1- Configuración a través de notebook:
F- Operación: Pruebas de las Alarmas Externas
• Generar alarmas externas de 1 a 4 y confirmar a través del status de alarmas
42
![Page 43: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/43.jpg)
MMO4E1 Ad
![Page 44: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/44.jpg)
MMO 4E1AdPresentación
Transporte de hasta 4 tributários de 2 Mbps;
Transporte de servicio V.35 / V.36 o Ethernet 10 / 100;
Exteriorización de alarmas y status por leds;
Configuración y supervisión por notebook;
Geréncia SNMP (Agente embutido o Agente Proxy).44
![Page 45: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/45.jpg)
MMO 4E1Ad Presentación
PANEL FRONTAL
PANEL DE LEDS
45
![Page 46: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/46.jpg)
MMO 4E1Ad Presentación
PANEL TRASERO
46
![Page 47: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/47.jpg)
MMO 4E1Ad Interfaces Ópticas
LED
LASER
LASER BIDIRECCIONAL
ST-PC
E2000
SC-APC
CONECTORES:
47
![Page 48: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/48.jpg)
MMO 4E1Ad Interfaces Ópticas
48
![Page 49: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/49.jpg)
MMO 4E1Ad Interfaces Ópticas
49
![Page 50: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/50.jpg)
MMO 4E1Ad Interfaces Elétricas
TX NEGATIVOTX POSITIVO
MALHA RXRX POSITIVO
NCNCMALHA TX
RX NEGATIVO
6.0
6.0
3.0
Dobrar Malha para trás.
Soldar
CONECTOR IEC 169-13 (75Ω) CONECTOR RJ-45 (120Ω)
50
![Page 51: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/51.jpg)
MMO 4E1AdAlimentación
Alimentación Full-Range:
• DC: - 48V ± 25% (-36 ~ -60 VDC)
• AC: 90 ~ 250 VAC
Consumo: 12 W (configuración 1+1)
Fase de Operación: MMO 4E1: 0º a 50º C
MMO 4E1-XT: -10º a 65º C
Configuración de los cables de alimentación:
51
![Page 52: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/52.jpg)
MMO 4E1Ad Canal de Servicio
Voz
Datos
• RS 232
• Tasa de hasta 19200 bps, asincrónico
• Transparente e independiente de protocolo
5.GND3.TX2.RX
52
![Page 53: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/53.jpg)
MMO 4E1AdInterfaz de Configuración
Acceso através de panel frontal (19200bps) o AUX1;
Interfaz RS-232 con conector DB9 para conexión de PC;
Terminal VT-100;
Realización de configuración / testes en el enlace;
Atualización de Software (panel frontal).
53
![Page 54: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/54.jpg)
MMO 4E1AdAlarmas Externas / Urgentes
Recolección de hasta 4 alarmas externas
Exteriorización de Alarma Urgente y Alarma No Urgente
Contacto seco de relay
ALARMES
T.48VALEX 4
ALEX 3ALEX 2
ALEX 1
AU ANU
54
![Page 55: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/55.jpg)
MMO 4E1AdInterfaz Nx64
Interfaz V.35 (padrón)
Placa multiprotocolo: V.35 / V.36 / V.28 / V.11 / X21 / RS530 / RS530A
Interfaz E1 → Entrada de reloj externo
55
![Page 56: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/56.jpg)
MMO 4E1AdInterfaz Nx64
Conexión Punto a Punto
ETD ETD
Nx64 Nx64
N64MMO4E1Ad
N64MMO4E1Ad
FO
56
![Page 57: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/57.jpg)
MMO 4E1AdInterfaz Nx64
Conexión utilizando Red Pública
ETD
ETD
Nx64
Nx64
G703MMO4E1Ad
FO
RED PUBLICA
N64
MMO4E1Ad
MMO4E1Ad G703MMO4E1Ad
FON64
57
![Page 58: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/58.jpg)
MMO 4E1AdInterfaz Nx64 - Alarmas
TD (103) : Falta de señal em la transmición del ETD RD (104) : Falta do sinal na recepção do ETD
CTS (106) “Clear to Send”: ECD indica al ETD que puede transmitir datos.
DCD (109) “Data carrier Detect”: ECD indica al ETD que está en condiciones operacionales.
58
![Page 59: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/59.jpg)
MMO 4E1AdMódulo LAN
Velocidad de 2 Mbps;
Interfaz Ethernet 10baseT / 100BaseT, Half duplex / Full duplex;
Autonegociación;
Función Bridge (Direcciones MAC: 1024 direcciones);
Control de flujo;
Capacidad de buffer: 32 kbytes;
Función LIN (Link Integrity Notification);
Compatible com normas IEEE 802.3 y 802.1q.
59
![Page 60: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/60.jpg)
MMO 4E1AdMódulo LAN
LAN
MMO4E1Ad
LAN
MMO4E1AdFO
RED LOCALRED LOCAL
Conexión Punto a Punto
60
![Page 61: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/61.jpg)
MMO 4E1AdMódulo LAN
Conexión utilizando Red Pública
G703MMO4E1Ad
FO
RED LOCAL RED PUBLICA
LAN
MMO4E1Ad
RED LOCAL
MMO4E1Ad G703MMO4E1Ad
LAN FO
61
![Page 62: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/62.jpg)
MMO 4E1AdMódulo LAN - Alarmas
LINK : Interfaz Ethernet activa para la red LAN RX : Paquete IP recibido por la interfaz Ethernet TX : Paquete IP transmitido por la interfaz Ethernet
10/100 : apagado: Ethernet con tráfico 10Mbps verde: Ethernet con tráfico 100Mbps
62
![Page 63: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/63.jpg)
MMO 4E1AdDiagrama en Bloques
IDL
IDL
IDL
IDL
P
TROF.O
TRIBUTARIOS
GERENCIA Y CONTROL
DEMUX
MUX
DESEMBA-RALHADOR
EMBARA-LHADOR
SELECTOR
R
TROF.OTx
Rx
Rx
63
![Page 64: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/64.jpg)
MMO 4E1AdPrueba de Loopback – 2Mbps
Loopback de Interfaz
E1InterfazÓptica
MMO4E1Ad
Utilizado para probar el cableado y conectores
64
![Page 65: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/65.jpg)
MMO 4E1AdPrueba de Loopback – 2Mbps
Loopback de Enlace
E1
Interfaz Óptica
E1
MMO4E1Ad MMO4E1Ad
65
![Page 66: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/66.jpg)
MMO 4E1AdPruebas – Interfaz V.35
LAL : Loop Analógico Local (en la interfaz G.703) LDL : Loop Digital Local (en la interfaz V.35/V.36)
LDR : Loop Digital Remoto (en la interfaz V.35/V.36 remota) BERT: Inyección y Análisis de Errores para 2M
FOETDLOCAL
ETD REMOTOMMO4E1 Ad MMO4E1 Ad
V.35/V.36 V.35/V.36G.703
LALLDL LDR
66
![Page 67: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/67.jpg)
MMO 4E1AdPruebas – Interfaz V.35
LAL : Loop Analógico Local (interfaz G.703) LDL : Loop Digital Local (interfaz V.35/V.36)
RDL : Loop Digital Remoto (interfaz V.35/V.36 remota) BERT: Inyección y Análisis de Errores para 2M
67
![Page 68: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/68.jpg)
MMO 4E1AdGerencia
Protocolo SSX;
Geréncia SNMP - Agente Proxy o Agente Embutido;
Geréncia de Alarmas: cualquier software de gerenciamento que utilize el protocolo SNMP. (Se indica el software SNMPc);
Geréncia de Configuração: Terminal AsGa.
Switch(red ethernet)
Gerencia SNMPProtocolo
SSX
Protocolo SNMP MMO 4E1 Ad
Enlace Óptico
GERENTEProtocolo
SNMP
MMO 4E1 Ad
Enlace Óptico
MMO 4E1 AdAgente SNMP
MMO 4E1 Ad
Placa SNMP Interna
68
![Page 69: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/69.jpg)
MMO 4E1AdInterconexión - Supervisión de Red
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2 AUX1 AUX2
AUX1 AUX2
LOCAL A
LOCAL C
LOCAL B
LOCAL D
LOCAL E LOCAL F
A1
A2
C2
C1
B3
B2
B1
A3
LOCAL GFibra ópticaCable serial 69
![Page 70: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/70.jpg)
MMO 4E1AdInterconexión - Gerencia SNMP
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2 AUX1 AUX2
AUX1 AUX2
LOCAL A
LOCAL C
LOCAL B
LOCAL D
LOCAL E LOCAL F
A1
A2
C2
C1
B3
B2
B1
A3
LOCAL G
SNMP
Aggggg Pgggg
Agente SNMP - RoteadorAsGa
TXRXRXTXRX
interfazRS232
2
FALHARESET LIGTX LINKRX
interfazDE REDE
OPERAÇÃO
RedEthernet
Gggggggg
SNMP
Fibra ópticaCable serialCable UTP
70
![Page 71: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/71.jpg)
MMO 4E1AdCables de Geréncia
27
3
49
5
8
16
27
3
49
5
8
16
Supervisión Local Conector frontal: Supervisión Centralizada- AUX1:
Extensión de Geréncia AUX1-AUX1: Extensión de Geréncia AUX1-AUX2:
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
71
![Page 72: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/72.jpg)
MMO 4E1AdConfiguración Inicial
Configuración del Tipo de Interfaz Eléctrica
ON - 75 ΩOFF - 120 Ω
Configuración via hardware + comando via software
Configuración via hardware:
72
![Page 73: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/73.jpg)
MMO 4E1AdConfiguración Inicial
Configuración de los Pines del Conector de Datos
El Canal de Comunicación de Datos sólo funciona se no hay unmonofono insertado en el jack del panel frontal.
73
![Page 74: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/74.jpg)
MMO 4E1AdConfiguración Inicial
Switches utilizados:
74
![Page 75: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/75.jpg)
MMO 4E1AdConfiguración Inicial
Pasos para la Configuracion:
B
LOS
M
LOS
FORCEDSWITCH
1
2
46
8
35
7
9
75
![Page 76: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/76.jpg)
MMO 4E1AdConfiguración Inicial
• 1° paso: Dirección
• 2° paso : Dirección
• 3° paso : Designación, modo y tasa de comunicación
• 4° paso : Fuentes y Geréncia Extendida
• 5° paso : LSIA, Tipo del Modem Remoto y Módulos
• 6° paso : Módulo Nx64
• 7° paso : Módulo Nx64
• 8° paso : Módulo Nx64
• 9° paso : Módulo Nx64
76
![Page 77: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/77.jpg)
MMO 4E1AdConfiguración Inicial
Passo 1 - Dirección - 1a. parte:
• Led B titilando
• Configura los cuatro bits más significativos de la dirección• Ej.: Configuración de la Dirección 0010 0111 (39)
• Presione la llave de comutación forzada• Presione la llave de llamada para cambiar al paso 2
77
![Page 78: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/78.jpg)
MMO 4E1AdConfiguración Inicial
Paso 2- Dirección - 2a. parte:
• Led 10-6 titilando
• Configura los cuatro bits menos significativos de la dirección• Ej.: Configuración de la Dirección 0010 0111 (39)
• Presione la llave de comutación forzada• Presione la llave de llamada para cambiar al paso 3
78
![Page 79: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/79.jpg)
MMO 4E1AdConfiguración Inicial
Paso 3- Designación, Modo y Tasa de Comunicación:
• Led 10-3 titilando
DesignaciónModo Tasa de comunicación
• En el ejemplo : Modem A, 1+0, 1200 bps
Tasa de Comunicación:0 0 - 110 bps
0 1 - 1200 bps1 0 - 2400 bps1 1 - 4800 bps
A
B
1+1
1+0
1
0
1
0
79
![Page 80: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/80.jpg)
MMO 4E1AdConfiguración Inicial
Paso 4 - Fuentes de alimentación y Geréncia Extendida:
•Led LOS titilando
Número de FuentesDesactivado Desactivado
• En el ejemplo : 2 fuentes de alimentación habilitadas y geréncia extendida habilitada.
Geréncia Extendidahab
des
2
1
80
![Page 81: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/81.jpg)
MMO 4E1AdConfiguración Inicial
Paso 5 - LSIA, Tipo de Modem Remoto y Módulos:
• Led FORCED SWITCH titilando
LSIATipo de modem Módulo SNMP
• En el ejemplo : LSIA habilitada, Modem remoto de séries anteriores,
Módulo SNMP deshabilitado y Módulo Nx64 habilitado.
Módulo Nx64
Tipo de modem:1 - Modem séries nuevas
0 - Modem séries anteriores
hab.
des.
hab.
des.
1
0
81
![Page 82: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/82.jpg)
MMO 4E1AdConfiguración Inicial
Paso 6 - Módulo Nx64: JT16, CAS, CRC4 y Comandos por ETD:
• Led LOS titilando
JT16 para datosCAS CRC4
• En el ejemplo: JT16 habilitada para datos, Uso de CAS deshabilitado,
Uso de CRC4 deshabilitado y Recibimento de Comandos por ETD habilitado.
Comandos por ETD
habilitada
desabilitada
82
![Page 83: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/83.jpg)
MMO 4E1AdConfiguración Inicial
Paso 7 - Módulo Nx64: Relój e Inversión de Lógica de Datos:
• Led 10-3 titilando Relój Inversión de Lógica de Ascenso
• En el ejemplo: Relój Externo via Nx64, Inversión de Lógica de los Datos de Ascenso deshabilitada e Inversión de Lógica de los Datos
de Descenso habilitada.
Inversión de Lógica de Descenso
Origen de Relój:0 0 - Interno
0 1 - Recuperado1 0 - Externo via Nx641 1 - Externo via E1
hab.
des.
hab.
des.
1
0
1
0
83
![Page 84: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/84.jpg)
MMO 4E1AdConfiguración Inicial
Paso 8 - Módulo Nx64: Tipo de interfaz y Tasa Digital (1ra. parte):
• Led 10-6 titilando Tipo de
interfaz Nx64
• En el ejemplo: Tipo de interfaz Nx64: V.35 y Tasa Digital (1 1001): N= 25 - 1600 kbps.
1a. Parte de la tasa digital (N)0 0 0 - V.11
0 0 1 - RS530A0 1 0 - RS530
0 1 1 - X211 0 0 - V.351 0 1 - V.361 1 0 - V.28
1
0
1
0
1
0
1
0
84
![Page 85: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/85.jpg)
MMO 4E1AdConfiguración Inicial
Paso 9 - Módulo Nx64: Tasa Digital:
• Led M titilando
Tasa Digital N
• En el ejemplo: Tasa Digital (1 1001): N= 25 - 1600 kbps
1
0
1
0
1
0
1
0
N Kbps1 64 - 0 00012 128 - 0 00103 192 - 0 00114 256 - 0 01005 320 - 0 0101
28 1792 - 1 110029 1856 - 1 110130 1920 - 1 111031 1984 - 1 111132 2048 - 0 0000
85
![Page 86: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/86.jpg)
MMO 4E1AdInstalación
Embalaje• Manipular la caja con cuidado
• Utilizar herramientas cortantes con cautela para abrir la cinta adhesiva.
• El embalaje soporta pequeños choquesmecánicos y salpicaduras de agua.• Transporte a largas distancias.
Presentación• Equipo
• Manual de operación• Cable tripolar• Kit de fijación
86
![Page 87: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/87.jpg)
MMO 4E1AdInstalación
Bastidor de 40U Bastidor de Pared
87
![Page 88: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/88.jpg)
MMO 4E1AdEjercicios Prácticos
Montaje de Setup:
Material utilizado:
• 2 MMO4E1Ad
• Fibras ópticas
• Cables coaxiales
E1MMO 4E1 Ad MMO 4E1 Ad
FO E1
Modem A Modem B
Analisadorde 2M
Loop físico
88
![Page 89: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/89.jpg)
MMO 4E1AdEjercicios Prácticos
Setup:
Verificar a través de los leds en el panel frontal:
• Status de la interfaz óptica
• Status de las interfaces eléctricas
• Status del equipo remoto através de la llave LOC/REM
Probar:
• Canal de servicio
• Comutación óptica
E1MMO 4E1 Ad MMO 4E1 Ad
FO E1
Modem A Modem B
Analisadorde 2M
Loop físico
89
![Page 90: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/90.jpg)
MMO 4E1AdEjercicios Prácticos
1- Configuración através del panel frontal (via hardware):
Realizar las siguientes configuraciones:
• Dirección del enlace: 10
• Modem local como A
• Modem remoto como B
• Modo de operación: 1+1
• Velocidad serial: 4800
• Número de fuentes: de acuerdo con el equipo
• Gerencia extendida: habilitar
• SIA en caso de loop óptico: caso sea bidi → habilitar
• Módulo SNMP: deshabilitar
90
![Page 91: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/91.jpg)
MMO 4E1AdEjercicios Prácticos
1- Configuración através del panel frontal (via hardware):
Caso haya módulo N64, realizar las siguientes configuraciones:
• Módulo N64: habilitar
• JT16: para señalización
• CAS: habilitar
• Comando por ETD: deshabilitar
• Relój: Modem A: interno; Modem B: recuperado
• Lógica de datos: normal
• Interfaz: V.35
• Tasa digital: 640 kbps
91
![Page 92: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/92.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
A- Status:
Verificar através del Terminal AsGa:
• Status de alarmas
• Status de la configuración (confirmar la configuración realizada via hardware)
• Fecha / hora
• Dirección através de la puerta frontal
92
![Page 93: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/93.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
B- Configuraciones del enlace:
Configurar:• Nombre para el enlace• Alterar la dirección a 1
• Tasa serial 1200• Tiempo de retorno de la comutación 10s
• Modo de operación 1+1• Gerencia extendida: habilitar
• SIA en caso de loop óptico: habilitar• Idioma: português• Ajustar fecha/hora
93
![Page 94: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/94.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
C- Configuraciones de modem:
Configurar:
• Nombre para los modems A y B
• Modem local como A
• Tipo de modem remoto: Ad
• Fuentes de alimentación: Modem A:1; Modem B:2 (verificar alarma de ausencia de fuente en modem B)
• Impedáncia: 75 Ω
• Código de línea: HDB3
94
![Page 95: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/95.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
C.1- Configuraciones de modem:
Configurar:
• Modem A: Alarma externa 1, no urgente, puerta abierta
• Modem B: Alarma externa 3, urgente, calentamiento
Generar las alarmas externas configuradas y confirmar através del status de alarmas y configuración.
95
![Page 96: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/96.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
D- Módulo N64:
Caso exista módulo N64, configurar:
• Tasa digital: 1600 kbps
• CAS: deshabilitar
• JT16: datos
• CRC4: habilitar
• Canales no utilizados: IDLE
• Fuente de relój: Modem A: externo N64, Modem B: recuperado
• Confirmar las configuraciones através del Status
96
![Page 97: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/97.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
E- Operación: Prueba de Reset
Realizar:
• Reset de geréncia (verificar que no hay interrupción de tráfico)
• Reset de hardware (verificar que hay interrupción de tráfico)
97
![Page 98: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/98.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuração através de notebook (via software):
E.1- Operación: Prueba de Loopback
Realizar:
• Loopback de interfaz en el canal 1 del modem local
Verificar através del Analisador
Realizar:
• Loopback de enlace en el canal 4 del modem remoto
Verificar através del Analisador
Desactivar el loopback através del reset de comandos
98
![Page 99: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/99.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
E.2- Operación: Pruebas de comutación forzada
• Realizar, através del comando, la comutación forzada para la reserva en el modem local
• Verificar através de los leds y del status de alarmas
• Realizar, através del comando, la comutación forzada para la reserva en el modem remoto
• Verificar através de los leds y del status de alarmas
• Realizar comutación forzada através de la llave presente en el panel frontal
• Verificar el tiempo de retorno de la comutación (10s)
99
![Page 100: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/100.jpg)
MMO 4E1AdEjercicios Prácticos
2- Configuración através de notebook (via software):
F- Operación: Prueba en la interfaz N64 (caso utilizada)
Realizar:
• Loopback digital local y verificar através del Analisador
• Loopback analógico y verificar através del Analisador
• Loopback digital remoto y verificar através del Analisador
• Prueba de BERT y Loopback digital remoto. Verificar la prueba através del led BERT (verde: ok; rojo: falla)
100
![Page 101: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/101.jpg)
AX4E1
101
![Page 102: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/102.jpg)
Entrenamimento AX 4E1
Entrenamiento AX 4E1
102
![Page 103: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/103.jpg)
AX4E1Presentación
103
![Page 104: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/104.jpg)
AX4E1 Presentación
104
![Page 105: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/105.jpg)
AX4E1 Gabinete
Concentra hasta 16 conjuntos MUX4 y 2MUX2;
Entradas de alimentación;
Placas Filtro;
Placa de Gerencia;
RJ-45 para gerencia SNMP;
Tapa de protección: Ventiladores y Lámparas de Advertencia.
105
![Page 106: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/106.jpg)
AX4E1 Placa MUX4
Características Generales del Conjunto MUX4:
• Transporte de hasta 4 tributários (modem 4E1);
• Configuración de protección;
• Canal de servicio: voz / datos;
• Pruebas de loopback;
• Exteriorización de alarmas y estado - Leds / Gerencia;
• Gerencia SNMP.
Compatíble con todas las versiones de MMO4E1.
106
![Page 107: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/107.jpg)
AX4E1 Placa MUX4
Principales Diferencias en Relación al MMO4E1:
• No posee V.35 / LAN;
• No posee recolección de alarmas externas;
• Configuración / pruebas a través del agente Proxy (conector frontal / telnet);
• Dirección fija de 1 a 16 (de acuerdo con el slot ocupado);
• Posee solamente los comandos principales del MMO 4E1;
• Atualización de software via EPROM;
107
![Page 108: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/108.jpg)
AX4E1 Placa 2MUX2
Características generales del Conjunto 2MUX2:
• Transporte de tributários G.703 (2 Links);
• Pruebas de loopback;
• Exteriorización de alarmas y status - Leds / Gerencia;
• Gerencia SNMP;
• Atualización de software via download.
Compatible con las versiones de MMO2E1 Ad y MMOFlex.
108
![Page 109: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/109.jpg)
AX4E1 Placa 2MUX2
Principales Diferencias en relación al MMO2E1:
• No posee interfaz LAN / V.35;
• No posee recolección de alarmas externas;
• Configuración / pruebas a través de agente Proxy (conector frontal / telnet);
• Dirección fija de 1 a 32 (de acuerdo con el slot ocupado);
109
![Page 110: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/110.jpg)
AX4E1 Placa Filtro
Filtrado de las entradas de alimentación;
Fusible de protección.
110
![Page 111: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/111.jpg)
AX4E1 Placa de Gerencia
Control y monitoría de todos los conjuntos MUX;
Alimentación y monitoría del ventilador y lámpara
de advertencia;
Agente Proxy embutido (Gerencia SNMP);
Emulación VT-100;
Acceso a la configuración a través del conector DB9;
Selección del enlace para uso del canal de servicio
y entrada de monofono (conjunto MUX4);
Alimentación de emergencia para hasta 4 placas MUX.
111
![Page 112: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/112.jpg)
AX4E1 Alimentación
2 conversores DC;
Alimentación DC: - 48V ± 25% (36~60VDC);
Protección contra sobretensión y sobrecorriente
en la salida;
Consumo: 120 W.
112
![Page 113: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/113.jpg)
LED LASER LASER BIDIRECCIONAL
SC-PC SC-APC E2000
CONECTORES:
AX4E1 Interfaces Ópticas
113
![Page 114: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/114.jpg)
AX4E1 Interfaces Ópticas
Transceptor Característica UnidadeAtenuação do enlace 0 a 17 dBAlcance estimado 0 a 45 kmComprimento de onda 1300 nm
LASERFaixa 2
Fibra Monomodo Conector SC ou STAtenuação do enlace 5 a 26 dBAlcance estimado 15 a 75 kmComprimento de onda 1300 nm
LASERFaixa 3
Fibra Monomodo Conector SC ou STAtenuação do enlace 0 a 11 dBAlcance estimado 0 a 30 kmComprimento de onda 1300 nm
LASER BidirecionalFaixa 2
Fibra MonomodoConector E2000 ou SC/APCAtenuação do enlace 0 a 20 dBAlcance estimado 0 a 55 kmComprimento de onda 1300 nm
LASER BidirecionalFaixa 3
Fibra Monomodo Conector E2000 ou SC/APCAtenuação do enlace 0 a 10 dBAlcance estimado 0 a 40 kmComprimento de onda 1550 nm
LASER BidirecionalFaixa W2
Fibra Monomodo Conector E2000 ou SC/APCAtenuação 0 a 12 dBAlcance estimado / reserva 1 km 0 a 2 kmComprimento de onda 850 nm
LED(4)
Fibra Multimodo.85 Conector SC ou ST
Atenuação 0 a 6 dBAlcance estimado / reserva 1 km 0 a 2 kmComprimento de onda 1300 nm
LED(4)
Fibra Multimodo1.3 Conector SC ou ST
114
![Page 115: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/115.jpg)
AX4E1 Interfaces Eléctricas
2048 kbps ± 50 ppm; Interfaces G.703 - 75 Ω ó 120 Ω.
115
![Page 116: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/116.jpg)
AX4E1 Alarmas Urgentes y No Urgente
Exteriorización de Alarma Urgente y Alarma No Urgente;
Contacto Seco de Relay;
Exteriorización de alarmas del gabinete.
116
![Page 117: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/117.jpg)
AX4E1 Gerencia SNMP
Switch(red ethernet)
Gerencia AsGaVision
Protocolo SNMP
AX 4E1
Enlace Óptico
MMO 2E1
MMO 2E1
GERENTE
MMO 4E1
Protocolo SNMP
MMO 2E1 Ad MMO 2E1 AdAgente SNMP
MMO 4E1
Gerencia de Alarmas: cualquier software de gerenciamento que utilize el protocolo SNMP. (Se recomienda el software SNMPc);
Configuración via telnet
117
![Page 118: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/118.jpg)
AX4E1 Interconexión – Gerencia de Red
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
LOCAL A
LOCAL C
LOCAL B
LOCAL D
LOCAL E LOCAL F
C2
C1
B3
B2
B1
LOCAL G
AX 4E1
118
![Page 119: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/119.jpg)
AX4E1 Cables de Gerencia
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
Supervisión Local Conector frontal: Supervisión Centralizada- AUX1:
Extensión de Gerência AUX1-AUX1: Extensión de Gerencia AUX1-AUX2:
27
3
49
5
8
16
27
3
49
5
8
16
119
![Page 120: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/120.jpg)
AX4E1 MUX4 – Configuración Inicial
Configuración de los Pines del conector DB17
Canal 1: Entrada - pino 1, Malla - pino 19Salida - pino 2, Malla - pino 20
Canal 2: Entrada - pino 3, Malla - pino 21Salida - pino 4, Malla - pino 22
Canal 3: Entrada - pino 5, Malla - pino 23Salida - pino 6, Malla - pino 24
Canal 4: Entrada - pino 7, Malla - pino 25Salida - pino 8, Malla - pino 26
120
![Page 121: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/121.jpg)
AX4E1 MUX4 – Configuración Inicial
Configuración Impedancia
121
![Page 122: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/122.jpg)
AX4E1 MUX4 – Configuración Inicial
Configuración de los Pines del Conector de Datos
• El Canal de Comunicación de Datos sólo funciona si el conjunto encuestión no está seleccionado para el canal de voz.
122
![Page 123: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/123.jpg)
AX4E1 MUX4 – Configuración Inicial
Configuración a través del Panel Frontal
123
![Page 124: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/124.jpg)
AX4E1 MUX4 – Configuración Inicial
Switches utilizados:
124
![Page 125: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/125.jpg)
AX4E1 MUX4 – Configuración Inicial
Pasos de Configuraciones:
LOSLOS
10-310-6
MB Passo 3
Passo 2
Passo 1
125
![Page 126: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/126.jpg)
AX4E1 MUX4 – Configuración Inicial
Pasos de Configuraciones:
• 1° paso: Designación, Modo y Tasa de Comunicación;
• 2° paso: Tipo del Modem Remoto y Tiempo de Retorno de
Conmutación;
• 3° paso: Gerencia Extendida, LSIA e Idioma.
126
![Page 127: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/127.jpg)
AX4E1 MUX4 – Configuración Inicial
Designación, Modo y Tasa de Comunicación:
• Led 10-3 titilando
DesignaciónModo
Tasa de comunicación
• En el ejemplo: Modem A, 1+0, 1200 bps
Tasa de Comunicación:0 0 - 110 bps0 1 - 1200 bps1 0 - 2400 bps1 1 - 4800 bps
B A
1+11+0
10
10
127
![Page 128: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/128.jpg)
AX4E1 MUX4 – Configuración Inicial
Modem Remoto y Tiempo de Retorno de Conmutación:
• Led LOS titilando
Tipo del Modem Remoto:1 - MMO4E1 S2000 o Ad0 - Modem séries anteriores
0 1
10
Tiempo de Retornode Conmutación
• En el ejemplo: Modem Remoto MMO4E1 Ad o S2000 y Tiempo deRetorno de Conmutación de 1 min.
10
10
Tiempo de Retornode Conmutación:
0 0 0 - 10s0 0 1 - 1 min0 1 0 - 5 min0 1 1 - 10 min1 0 0 - 15 min1 0 1 - Infinito
128
![Page 129: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/129.jpg)
AX4E1 MUX4 – Configuración Inicial
Gerencia Extendida, LSIA e Idioma:
• Led M titilando
Gerencia Extendida 0 1
HabDes
• En el ejemplo: Gerencia Extendida habilitada, LSIA deshabilitada e Idioma español.
10
10
Idioma:
0 0 - Portugués0 1 - Español1 0 - InglésLSIA
Idioma
129
![Page 130: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/130.jpg)
Tabla Resumida del modo de configuración
130
![Page 131: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/131.jpg)
AX4E1 2MUX2 – Configuración Inicial
Configuración de la Impedancia
1 2 3 4 5 6 7 8ON - 7 5 Ω
OFF - 1 2 0 Ω
CHV4
1 2 3 4 5 6 7 8
75 75 75 75CHV5
120
120
120
120
JP3
131
![Page 132: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/132.jpg)
AX4E1 SNMP – Configuración Inicial
Configuración de los Pines de la interfaz SNMP
1 – Tx Positivo
876 – Rx Negativo543 – Rx Positivo2 – Tx Negativo
132
![Page 133: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/133.jpg)
AX4E1 Instalación
Embalaje• Manipular la caja con cuidado• Utilizar herramientas cortantes con cautela para la abertura de la cinta adhesiva.• El embalaje soporta pequeños choquesmecánicos y salpicaduras de agua.• Transporte a largas distancias.
Presentación• Equipo• Manual de operación• Cable tripolar• Kit de fijación
133
![Page 134: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/134.jpg)
AX4E1 Instalación
Bastidor de 40U
134
![Page 135: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/135.jpg)
Agente PROXY
135
![Page 136: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/136.jpg)
136
![Page 137: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/137.jpg)
PROTOCOLO SNMP(Simple Network Management Protocol)
• Protocolo de gerenciamento desarrollado para operar sobre equipos de red basados en TCP / IP.
• Agente: recibe, procesa y responde a solicitudes da gerencia. Genera informaciones de eventos internosal sistema.
• MIBs (Management Information Bases): describe las variábles de gerenciamento y el tipo de operación que el cliente puede ejecutar sobre cada variable del sistema.
137
![Page 138: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/138.jpg)
Sistema de Gerencia
Conversor de protocolo SNMP para los protocolos SSX y VT100
Red de modems AsGA
RED SNMP Switch
SNMP Agente Proxy
GerenciaCentralizada
SNMP
Protocolo SSX
TELNET
ggggg IP
TXAgente SNMP - RoteadorAsGa
TXRXRXTXRX
interfazRS232
2
FALHARESET LIGTX LINKRX
interfazDE REDE
OPERAÇÃO
138
![Page 139: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/139.jpg)
• Gerenciamento de hasta 32 enlaces:
• a través de un terminal VT100;
• a través del protocolo TELNET (acceso remoto via TCP/IP);
• a través de AsGaVision.
• a través de cualquier software de gerencia SNMP.
SNMP Agente Proxy
139
![Page 140: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/140.jpg)
PANEL FRONTAL
PANEL TRASERO
SNMP Agente Proxy
140
![Page 141: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/141.jpg)
ALIMENTACIÓN
• Alimentación Full-Range:
• DC: - 48V ± 25% (-36 ~ -60 VDC)
• AC: 90 ~ 250 VAC
• Fusíble de protección instalado en la placa junto a la fuente.
• Consumo: 5 W
• Configuración de los cables de alimentación:
141
![Page 142: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/142.jpg)
CONECTOR RJ-45
NCNCmalha TX
RX negativo
TX PositivoTX negativoMalha RXRX positivo
CONECTOR RJ45
142
![Page 143: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/143.jpg)
GERENCIA EXTENDIDA
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2
AUX1 AUX2 AUX1 AUX2
AUX1 AUX2
LOCAL A
LOCAL C
LOCAL B
LOCAL D
LOCAL E LOCAL F
A1
A2
C2
C1
B3
B2
B1
A3
LOCAL G
AUX1AgenteSNMP
AUX2 AUX3
143
![Page 144: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/144.jpg)
CABLES DE GERENCIA
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
27
3
49
5
8
16
Supervisión Local Conector frontal: Conexión AUX1 (SNMP) - AUX1 (modem):
Extensión de Gerencia AUX1-AUX1: Extensión de Gerencia AUX1-AUX2:
27
3
49
5
8
16
27
3
49
5
8
16
144
![Page 145: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/145.jpg)
CONFIGURACIÓN INICIAL
• Acceso:
• Como administrador (admin) o usuário (user).------------------------------------------------------------------------------- AA GGGGG AAAA GGGGGGG AA AA GG GG AA AA GG GG AA AA SSSSS GG AAAA AA AA SS SS GG A AA AAAAAAAAAA SS GG GGGGGG AA AA AA SSSSS GG GG AAAAAA AA AA SS GG GGGG AA AA AA AA SS SS GGGGGGG G A AAA AA AA SSSSS GGGGG G AAAA A
AsGa S.A.
Agente Procurador SNMP - Versao X.XX
Login
------------------------------------------------------------------------------- 145
![Page 146: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/146.jpg)
CONFIGURACIÓN INICIAL
• Inicialización de la Gerencia:-------------------------------------------------------------------------------
Menu Principal (Conexoes TCP em uso: 1 de 3)
Configuracao do Agente Procurador SNMP
Configuracao dos Modens Opticos
Supervisao
Salvar Alteracoes
Reseta Agente Procurador SNMP
Logout
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
146
![Page 147: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/147.jpg)
• Configuración del SNMP Agente Proxy:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Menu de Configuracao
Informacoes Gerais do Sistema
Configura SNMP
Configura Porta Serial
Configura Enderecos IP
Configura Parametros do Terminal
Configura Parametros de Gerencia
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
147
![Page 148: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/148.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Informacoes Gerais do Sistema
Apresentar Informacoes
Alterar Informacoes
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
148
![Page 149: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/149.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Apresenta Informacoes do Sistema
Agente.......: SNMP Proxy Agent AsGa End. MAC.....: 02 00 01 02 03 04 End. IP......: 1.2.3.4 Agente Versao: 5.0P Data.........: 28/10/2003 Hora.........: 14:05:54 Nome.........: Contato......: Localizacao..: Fontes Monit.: DC1 DC2
-------------------------------------------------------------------------------
• Configuración do SNMP Agente Proxy:
149
![Page 150: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/150.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configuracoes SNMP
Configuracao das TRAPs
Comunidades SNMP
Protecao de Polling
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
150
![Page 151: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/151.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configuracao das TRAPs Geracao de TRAPs ( HABILITADA )
Periodo de Envio ( 60 segundos )
Config. Destino TRAPs 1 ( 10.0.10.191 )
Config. Destino TRAPs 2 ( 10.0.50.57 )
Config. Destino TRAPs 3 ( --.--.--.-- )
Config. Destino TRAPs 4 ( --.--.--.-- )
Config. Destino TRAPs 5 ( --.--.--.-- )
Config. Destino TRAPs 6 ( --.--.--.-- )
Voltar------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
151
![Page 152: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/152.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Destino das TRAPs 1
Operacao: ENVIO PERIODICO
Endereco: ( 10.0.10.191 )
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
152
![Page 153: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/153.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configurar Comunidades SNMP
Comunidade de Leitura ( public )
Comunidade de Escrita ( private )
Comunidade de Traps ( public )
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
153
![Page 154: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/154.jpg)
CONFIGURACIÓN INICIAL
------------------------------------------------------------------------------- Protecao de Polling
Identificador de objeto ( 1.3.6.1.2.1.1.2.0 )
Intervalo de protecao ( 0 segundos )
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
154
![Page 155: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/155.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configuracao da porta serial da Rede de Modens
Status da Porta
Mudar Baud Rate
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
155
![Page 156: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/156.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Status da porta serial da Rede de Modens
Baud Rate = 1200 Paridade = Par Stop Bits = 1 Data Bits = 8
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
156
![Page 157: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/157.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
CONFIGURACOES IP
Endereco IP ( 1.2.3.4 )
Gateway Default ( 1.2.3.1 )
Mascara Subnet ( 255.0.0.0 )
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
157
![Page 158: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/158.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configuracao do Terminal
Altera Senhas do Terminal
Configura Timeout de Utilizacao
Configura Timeout de Conexao TCP
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
158
![Page 159: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/159.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Mudanca de Senhas do Sistema
Mudar senha administrativa
Mudar senha do usuario
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
159
![Page 160: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/160.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Ajuste de Timeout de Utilizacao do Terminal
Entre com o novo valor (Atual:180s min:5s max:600s):
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
160
![Page 161: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/161.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Ajuste do Timeout de Conexao TCP - Telnet
Entre com o novo valor (Atual: 10 minutos; 1 - 10 minutos):
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
161
![Page 162: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/162.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configura Parametros de Gerencia
Fator de Atraso
Fator de LinkDown
Fator de Balanceamento
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
162
![Page 163: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/163.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
FATOR DE ATRASO
Valor Atual: 1
Forneca o novo fator (min:1 max:10):
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
163
![Page 164: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/164.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
FATOR DE LINKDOWN
Valor Atual: 5
Forneca o novo fator (min:3 max:10):
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
164
![Page 165: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/165.jpg)
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
FATOR DE BALANCEAMENTO
Valor Atual: 30
Forneca o novo fator (min:1 max:100):
-------------------------------------------------------------------------------
• Configuración del SNMP Agente Proxy:
165
![Page 166: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/166.jpg)
• Configuración de los Modems Ópticos:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Configuracoes dos Modens Opticos
Habilita Enlace
Desabilita Enlace
Enlaces Habilitados
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
166
![Page 167: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/167.jpg)
• Configuración de los Modems Ópticos:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Habilitacao dos Modens Opticos
Entre com o endereco do Sistema: 10 Entre com o Nome/Localizacao do Enlace: MMO16E1 Entre com a localizacao do Modem A: Estacao A Entre com a localizacao do Modem B: Estacao B
Selecione o tipo de modem
Modem 2E1 Modem 4E1 Modem FLEX Modem 16E1 Modem 16E1B Conversor n64 Sair------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>------------------------------------------------------------------------------- 167
![Page 168: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/168.jpg)
• Configuración de los Modems Ópticos:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Desabilitacao dos Modens Opticos
Entre com o endereco do Enlace: 3
--> Enlace desabilitado <--
-------------------------------------------------------------------------------
168
![Page 169: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/169.jpg)
• Configuración de los Modems Ópticos:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Enlaces Habilitados
Todos os tipos de enlaces
Enlaces de Modens 2E1
Enlaces de Modens 4E1
Enlaces de Modens FLEX
Enlaces de Modens 16E1
Enlaces de Modens 16E1B
Enlaces de Conversores n64
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
169
![Page 170: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/170.jpg)
• Menu de Supervisión:
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Menu de Supervisao
Alarmes dos Enlaces
Alarmes do Agente Proxy
Emulacao do Terminal VT100
Voltar
------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
170
![Page 171: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/171.jpg)
• Menu de Supervisión :
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Enlaces de Modens com Alarmes Ativos
Endereco Tipo Nome Enlace/Localiza
010 16xE1 MMO16E1 011 4xE1 MMO4E1Ad
Pagina 1 de 1------------------------------------------------------------------------------- Use as teclas de direcao na escolha da opcao do menu Apos escolher o item pressione <ENTER>-------------------------------------------------------------------------------
171
![Page 172: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/172.jpg)
• Menu de Supervisión :
CONFIGURACIÓN INICIAL
-------------------------------------------------------------------------------
Alarmes do Agente Proxy
Falha na fonte DC2
-------------------------------------------------------------------------------
172
![Page 173: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/173.jpg)
INSTALACIÓN
• Embalaje- Manipular la caja con cuidado- Utilizar herramientas cortantes con
cautela para la apertura de la cinta adhesiva.- El embalaje soporta pequeños choques
mecánicos y salpicaduras de agua.- Transporte a largas distâncias.
• Presentación- Equipo- Manual de operación- Cable tripolar- Kit de fijación
173
![Page 174: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/174.jpg)
INSTALACIÓN
• Bastidor de 40U • Bastidor de Pared
174
![Page 175: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/175.jpg)
INSTALACIÓN
• Bastidor de 40U
175
...da semana que vem no brasil.
![Page 176: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/176.jpg)
CMN64
176
![Page 177: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/177.jpg)
EntrenamientoCMN64
177
![Page 178: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/178.jpg)
Convertidor de señal de tasas múltiples de 64 kbps para unaseñal E1 estructurado (G.704) ó no estructurado (G.703) concodificación de linea HDB3;
Interfaces disponibles: V.35 e V.36;
Interfaces de transmisión: E1 G.703
Exteriorización de alarmas y status através de leds;
Facilidades de pruebas, controles y gerencia de los equiposlocales y remotos;
Opción de gerencia SNMP através de la placa CMGR (pararack de 3 ó 16 posiciones).
CMN64Presentación
178
![Page 179: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/179.jpg)
CMN64 Presentación
cuadro = 125 µs cuadro
PAQ 8bits 8bits 8bits8bits
Ventana
0 1 1PAQ
312PAQ
2 31
n x 64 kb/s 2048 kb/s
V.35 / V.36 G.703 / G.704
179
![Page 180: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/180.jpg)
CMN64 Mecanicas de los Conversores
Chassis de 1 slot
180
![Page 181: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/181.jpg)
• Alimentación Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarización ajustada automaticamente para alimentación DC.
• Posibilidad de redundancia de fuente;
• Configuración local via Dip-switch;
• Soporta supervisación y gerencia SNMP remotas;
• Mecanica: 9.5” por 1U.
CMN64 Mecanicas de los Conversores
Chassis de 1 slot
181
![Page 182: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/182.jpg)
CMN64 Mecanicas de los Conversores
Chassis de 3 slots
182
![Page 183: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/183.jpg)
CMN64 Mecanicas de los Conversores
Chassis de 3 slots
• Alimentación Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarización ajustada automaticamente para alimentación DC.
• Posibilidad de redundancia de fuentes através de la placa CMFT;
• Configuración local via Dip-switch;
• Gerencia SNMP através de la placa CMGR;
• Configuración y verificación de status via Web Browser (CMGR);
• Mecanica: 19” por 1U.
183
![Page 184: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/184.jpg)
CMN64 Mecanicas de los Conversores
Chassis de 16 slots
• CH-16 con placas filtro
184
![Page 185: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/185.jpg)
CMN64 Mecanicas de los Conversores
Chassis de 16 slots
• CH-16 sin placas filtro y 17 slot disponibles
185
![Page 186: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/186.jpg)
• Alimentación Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarización ajustada automaticamente para alimentación DC;
• Posibilidad de redundancia de fuentes através de la placa CMFT (proporciona energia para hasta 4 placas);
• Configuración local via Dip-switch;
• Gerencia SNMP através de la placa CMGR;
• Configuración y verificación de status via Web Browser (CMGR);
• Mecanica: 19” por 4U
CMN64 Mecanicas de los Conversores
Chassis de 16 slots
186
![Page 187: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/187.jpg)
Interfaz predeterminada: V.35 / V.36
Interfaces Opcionales: RS530A / RS530 / X21 / V.28 / V.11
Tasa Nx64 kbps, 1 ≤ N ≤ 32
Conector DB25
CMN64 Interfaz N64
187
![Page 188: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/188.jpg)
2048 kbps ± 50 ppm
Interfaces G.703 75 Ω ó 120 Ω configurable
Conectores IEC 169-13 ó BNC y RJ45
CMN64 Interfaz Elétrica G.703
188
![Page 189: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/189.jpg)
Cada placa de los Conversores posee una fuente interna.
Alimentación Full-Range:
• DC: - 48V ± 25% (-36 a -60 VDC)
• AC: 90 ~ 250 VAC
Opción de fuente redundante en la mecanica;
Consumo: 6W.
CMN64Alimentación
189
![Page 190: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/190.jpg)
CMN64 Configuración Punto a Punto
ETD ETDCMn64 CMn64
E1
REDEETD ETDE1E1
CMn64 CMn64
190
![Page 191: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/191.jpg)
CMN64 Configuración en Cascada
RED E1
V.35 / V.36 G.703 ABC (2 Mbps)
A’B’C’ (2Mbps)
(2 Mbps)
(2 Mbps)
A’BC
A’B’C
A
B’
B
C
C’
A’
191
![Page 192: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/192.jpg)
CMN64 Configuración en Cascada
SDH
Loc. C
128k
384k
1024k
128k384k1024k
4 x E1
16 x E1
12 E1
1 x E1
4 x E1 2 x E1
1 x E1
E1E1
Grupo n 64(B)
Grupo n 64(A)
CMn64CMn64
CMn64
MMO4E1 PABX
PABX
MMO4E1MMO16E1MMO16E1ADM
ADM MMOFLEX
MMO2E1
MMO2E1 PABX
CMn64
CMn64
CMn64
Loc. BLoc. A
Loc. D Loc. E
Loc. F 1 x E1
192
![Page 193: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/193.jpg)
CMN64 Operación de los Leds – Señales de Alarmas
ETD E1
103 (TD) : Falta de señal en la transmisión del ETD 104 (RD) : Falta de señal en la recepción del ETD
RD
TD
193
![Page 194: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/194.jpg)
CMN64 Operación de los Leds – Señales de Control
106 (CTS) “Clear To Send”: ECD indica para ETD se puede transmitir datos. 109 (DCD) “Data Carrier Detect”: ECD indica para ETD que está en condiciones operacionales.
← DCD← CTS
ETD E1
194
![Page 195: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/195.jpg)
Led ON Verde: Placa alimentada corretamente
Rojo: Placa alimentada por la placa de gerencia
Apagado: Placa sin alimentación
Parpadeo de Luz: Plazo de funcionamiento vencido
Parpadeo en rojo apagado: Dirección no válida para rack
CMN64 Operaciones de los Leds
195
![Page 196: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/196.jpg)
Led Pruebas: El numero de veces que la led prueba se apaga indica que la prueba esta siendo executada
CMN64 Operación de los Leds
Boton RESETWarm reset: reset de la gerencia sin perdida de tráfico.
Se dispara el botón TEST en seguida o boton RST (en el máximo de 5 segundos despues)
Cold Reset: reset total de la placa con rápida interrupción de tráfico.
Se dispara el botón RST en seguida
196
![Page 197: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/197.jpg)
CMN64 Pruebas
LAL : Loop Analógico Local (en la Interfaz G.703) LDL : Loop Digital Local (en la Interfaz V.35/V.36) LDR : Loop Digital Remoto (en la Interfaz V.35/V.36 remota) BERT: Inyección y Anánalisis de Errores para el 2M
ETDLOCAL
ETD REMOTO
CMn64 CMn64
V.35/V.36 V.35/V.36G.703 G.703
LDRLDL LAL
RED E1
197
![Page 198: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/198.jpg)
CMN64 Pruebas
Prueba 1: LAL Loop Analógico Local (en la Interfaz G.703) Prueba 2: LDL Loop Digital Local (en la Interfaz V.35/V.36) Prueba 3: LDR Loop Digital Remoto (en la Interfaz V.35/V.36 remota) Prueba 4: BERT con RDL Inyección y análisis de errores para el 2M y Loop Digital Remoto Prueba 5: BERT Inyección y análisis de errores para el 2M
198
![Page 199: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/199.jpg)
Boton de prueba:De acuerdo con el tiempo de accionamiento del boton TEST,
podemos realizar 2 pruebas.
Tiempo de accionamiento
Prueba
Menor que 3 segundos
Deshabilita la prueba en la aplicación / informa version de software, firmware y
tipo de configuración
Prueba 1 Entre 3 y 6 segundos
Remoto Loopback en CMETH local
Prueba 2 Entre 6 y 9 segundos
Instalación Loopback en CMETH local
CMN64 Operación – Pruebas y Reset
199
![Page 200: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/200.jpg)
CMN64 Configuraciones
Tasa DigitalDefine cuantos canales deben ser asignados en virtud de E1 para transportar las informaciones resultante de interfaz Nx64.
200
![Page 201: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/201.jpg)
CMN64 Configuraciones
Uso de la JT16 Datos (PCM31 o UNFRAMED): La JT16 debe ser interpretada como cualquier otra Ventana de Tiempo.
Señalización (PCM-30): La JT16 no debe ser utilizada como canal,sólo se transmite la información de señalización.
201
![Page 202: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/202.jpg)
CMN64 Configuraciones
Uso del CAS (Señalización por Canal Asociado)
Determina si el equipo debe cambiar el contenido de la ventana de tiempo
16 (en el caso de PCM-30).
Habilitado: El equipo recupera las informaciones de MultiFrame
de la JT16, flecha que es la asignación de los canales y transmite estas
informaciones para adelantarse.
Deshabilitado: El equipo recupera las informaciones de MultiFrame
de la JT16 y las retransmite sin modificaciones.
202
![Page 203: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/203.jpg)
CMN64 Configuraciones
Uso del CRC4 (Cyclic Redundancy Check)Generación y evaluación del patrón para comprobar la señal de línea CRC,
cuando el equipo trabaja con PCM-30 ó PCM-31.
Habilitado: Cambios en el bit correspondiente al análisis de CRC4 en la JT0,
para evaluación en MultiFrame.
Deshabilitado: Poco cambia la correspondiente al análisis de CRC4 en la JT0.
203
![Page 204: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/204.jpg)
CMN64 Configuraciones
Canales No Utilizados Idle: Llena los canales con el código binario 11010101 (D5).
Retransmisión: Llena los canales con los valores leidos en la recepción.
204
![Page 205: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/205.jpg)
CMN64 Configuraciones
Canal InicialDefine cual debe ser el primer canal del cuadro E1 que se asignarán
al equipo
Canal Inicial 15
205
![Page 206: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/206.jpg)
CMN64 Configuraciones
Tipo de la Interfaz N64
Interfaz predeterminada: V.35 / V.36 ajuste via strap interno
Interfaces Opcionales: RS530A / RS530 / X21 / V.28 / V.11ajuste via dipswitch.
206
![Page 207: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/207.jpg)
CMN64 Configuraciones
Comandos por el ETD
Habilitado: Acepta las solicitudes de pruebas de ETD por la interfaz N64.
Deshabilitado: No acepta solicitudes de pruebas de ETD por la interfaz
N64.
OBS: La falta de conexión física entre las señales del Conversor y del ETD
genera las fluctuaciones que pueden interpretarse como una solicitud para
poner a prueba.
207
![Page 208: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/208.jpg)
CMN64 Configuraciones
Fuente del reloj: Interno: Obtenido por un oscilador interno del equipo; Recuperado: Obtenido del fase digital E1; Externo: Obtenido de la interfaz digital V.35/V.36.
OBS: En toda configuración sistematica debe haber apenasuna fuente del reloj.
208
![Page 209: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/209.jpg)
CMN64 Configuraciones Iniciales
Localización de las Dip-switches G.703
209
![Page 210: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/210.jpg)
CMN64 Configuraciones Iniciales
Tipo de Interfaz G.703
Configuración via Dip0
1ª Llave ON: entrada a tierra 1ª Llave OFF: entrada abierta 2ª Llave ON: salida a tierra 2ª Llave OFF: salida abierta 3ª y 4ª Llave ON: 75Ω 3ª ye 4ª Llave OFF: 120Ω
210
![Page 211: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/211.jpg)
CMN64 Configuraciones Iniciales
Tipo de Interfaz N64
Impedancia de entrada de la Interfaz N64
Impedancia de la salida de la Interfaz N64
Interfaz Nx64 JP505 JP506 JP508 JP515 JP516 JP517
V.35 1-2 1-2 1-2 1-2 1-2 1-2
V.36 2-3 2-3 2-3 2-3 2-3 2-3
Impedância de Entrada JP501 JP502 JP503 JP504
50 Ω 1-2 1-2 1-2 1-2
100 Ω - - - -
Elevada 2-3 2-3 2-3 2-3
Impedância de Saída JP509 JP510 JP511 JP512 JP513 JP514
50 Ω 1-2 1-2 1-2 1-2 1-2 1-2
100 Ω - - - - - -
Baixa 2-3 2-3 2-3 2-3 2-3 2-3
211
![Page 212: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/212.jpg)
CMN64 Configuraciones Iniciales
Aterramiento de Protección y de Referencia de la Señal N64Protección Hace la conexión a tierra por protección (del ETD) con la tierra de alimentación.
Referencia Hace la conexión de la referencia de la señal (para el ETD) con la tierra de alimentación.
Aterramento JP507
Aterramento de Proteção Nx64 1-2
Aterramento da Referência Nx64 2-3
212
![Page 213: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/213.jpg)
CMN64 Configuraciones Iniciales
• DIP1 • CHV1: CRC4OFF → Deshabilitado ON → Habilitado
• CHV2: JT16OFF → Datos ON → Señalización
• CHV3: CASOFF → Deshabilitado ON → Habilitado
• CHV4: Control de FlujoOFF → Deshabilitado ON → Habilitado
213
![Page 214: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/214.jpg)
CMN64 Configuraciones Iniciales
• DIP1 • CHV5: Inversión del Reloj de Transmisión(CT114)OFF → Normal ON → Invertida
• CHV6: Inversión del Reloj de Recepción (CT115)OFF → Normal ON → Invertida
• CHV7: Origen del Reloj RecuperadoOFF → Normal ON → Interfaz V.35/V.36
• CHV8: Tipo de RelojOFF → Interno ON → Recuperado
214
![Page 215: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/215.jpg)
215
CMN64 Configuraciones Iniciales
• DIP2
• CHV 1 a 5: Taxa DigitalN Kbps1 64 - 0 00012 128 - 0 0010
31 1984 - 1 111132 2048 - 0 0000
• CHV6 a 8: Tipo de protocolo
CH6 CH7 CH8 ProtocoloOFF OFF OFF V.11
OFF OFF ON RS530A
OFF ON OFF RS530
OFF ON ON X.21
ON OFF OFF V.35
ON OFF ON V.36/RS449
ON ON OFF V.28/RS232
ON ON ON Nenhum
215
![Page 216: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/216.jpg)
CMN64 Configuraciones Iniciales
• DIP3 • CHV 1 a 5: Canal InicialN Kbps1 64 - 0 00012 128 - 0 0010
31 1984 - 1 111132 2048 - 0 0000
• CHV6: Retransmisión de CanalesOFF → Idle ON → Retransmitir
216
![Page 217: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/217.jpg)
CMN64 Ejercicios Prácticos
Configuración de montaje:
Material utilizado:
1 CM n64
1 AX4E1 con placa 2MUX2
1 MMO2E1Ad con placa V.35
E1
E1
E1
V.35
V.35
217
![Page 218: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/218.jpg)
CMN64 Ejercicios Prácticos
1- Realizar las siguientes configuraciones:
• Taxa digital: 640 kbps
• Relógio: Conversor A: interno; Conversor B: recuperado
• JT16: para señalización
• CAS: habilitar
• CRC4: habilitar
• Canales no utilizados: IDLE
• Canal inicial: 13
218
![Page 219: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/219.jpg)
CMN64 Ejercicios Prácticos
2- Verificar el status de alarmas.
3- Insertar un analizador de datos y verificar la integridad del tráfico de datos.
219
![Page 220: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/220.jpg)
CMN64 Ejercicios Prácticos
4- Operación: Pruebas en la interfaz N64
Realizar:
• Loopback digital local y verificar através del Analizador
• Loopback analógico y verificar através del Analizador
• Loopback digital remoto y verificar através del Analizador
• Pruebas de BERT y Loopback digital remoto. Verificar las pruebas através del led BERT (Verde: ok; Rojo: falla)
220
![Page 221: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/221.jpg)
CMN64 Ejercicios Prácticos
4- Modificar los parametros de configuración conforme a lo deseado
221
![Page 222: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/222.jpg)
1
Apresentação ASGA
LINHA PDH NG e CONVERSORES DE MEIO
![Page 223: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/223.jpg)
2
Empresa brasileira468 colaboradores, sendo 11 no Exterior6000m2 áreaNBR ISO-9001:2000
![Page 224: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/224.jpg)
3
CARACTERÍSTICAS GERAIS Equipamentos NG
16 x E1s
V.35ETHERNET
34M
F.O.
MMO16E1NG:
PROXY NG
PROXY NG:
Endereços IPs de enlaces NG
REDE ETHERNER
T
![Page 225: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/225.jpg)
4
CARACTERÍSTICAS GERAIS Equipamentos CMs
CMSTM1
STM1 ELÉTRICOSTM1 ÓPTICO
CMTDC2ETHERNET E1 (2M)
CMETHETHERNET FIBRA ÓPTICA
CME3E3 (34M) FIBRA ÓPTICA
CMSTM1:
CMDTC2:
CMETH:
CME3:
CME3ETHERNET 10/100/100 FIBRA ÓPTICA – SFP GBCMGE:
![Page 226: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/226.jpg)
5
CARACTERÍSTICAS GERAIS Especificações de Alimentação
Alimentação Full-Range:
• DC: - 48V ± 25% (-36 ~ -60 VDC)
• AC: 90 ~ 250 VAC
Polarização ajustada automaticamente para alimentação DC
Fonte de Alimentação com Proteção contra sobretensão e sobrecorrente
* O equipamento AX4E1 possui alimentação diferente da Full-Range
![Page 227: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/227.jpg)
6
CARACTERÍSTICAS GERAIS Especificações de Alimentação
Consumos:
MMO16E1NG 18W
CMSTM1 5W
CMDTC2 6W
CMETH 6W
CME3 6W
CMGE 9W
INVERSE MUX 15W
PROXY NG 20W
![Page 228: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/228.jpg)
7
LED LASER LASER BIDIRECIONAL
SC-PC SC-APC E2000
CONECTORES:
CARACTERÍSTICAS GERAIS Interfaces Ópticas
![Page 229: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/229.jpg)
8
CARACTERÍSTICAS GERAIS Interfaces Ópticas
![Page 230: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/230.jpg)
9
CARACTERÍSTICAS GERAIS Interfaces Ópticas
![Page 231: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/231.jpg)
1 0
CARACTERÍSTICAS GERAIS Interfaces Ópticas
![Page 232: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/232.jpg)
1 1
CARACTERÍSTICAS GERAIS Interfaces Ópticas
SC/PCConector
nm1310 e 1550Comprimento de onda
km40Alcance estimado *
dB22Atenuação Máxima do enlace
dBm-34Sensibilidade Mínima
dBm-12Potência Óptica MínimaLASER (Lado A)
Tx1310/Rx1550(Lado B)
Tx1550/Rx1310Faixa 2
Fibra Monomodo
![Page 233: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/233.jpg)
1 2
LINHA PDH NG
![Page 234: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/234.jpg)
1 3
MMO16E1NG
![Page 235: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/235.jpg)
1 4
MMO 16E1 NG Apresentação
![Page 236: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/236.jpg)
1 5
MMO 16E1 NG Apresentação
Multiplexação de até: 16 tributários E1 a 2048Kbps G.703 (75 Ohms ou 120 Ohms); 1 Interface V.35 ou V.36 / V.11 (n x 64 kb/s); 1 Interface Brigde Ethernet 10/100 BaseT (n x 2 Mb/s); 1 Interface tributário E3 a 34368 Kbps G.703
Topologia de operação configurável: ponto a ponto, anel, em linha, regenerador ou conversor de interface (elétrica/óptica)
Função Inverse MUX (n x 2 Mb/s);
![Page 237: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/237.jpg)
1 6
Redundância opcional de interface de agregado óptico
Redundância opcional de fonte de alimentação
Exteriorização de alarme urgente
Coleta até 4 Alarmes Externos (Alarmes Ambientais)
MMO 16E1 NG Apresentação
![Page 238: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/238.jpg)
1 7
Configuração, testes e alarmes pelo LCD– Localização de remotos por nome e/ou IP
Réplica do display via SSH– Terminal de texto seguro com SSL
Servidor Web seguro (HTTPS)– Páginas de configuração, testes e estado
Agente SNMP V1, V2c, V3– Permite inclusive configuração– Traps V1 e V2
MMO 16E1 NG Apresentação
![Page 239: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/239.jpg)
1 8
E3
ETH
PORTA
CANAL
34M
34M
69M
E1
ETH
E3
MMO 16E1 NG Matriz de Configuração
V.35
![Page 240: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/240.jpg)
1 9
PAINEL FRONTALPAINEL FRONTAL
PAINEL TRASEIROPAINEL TRASEIRO
MMO 16E1 NG Apresentação
![Page 241: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/241.jpg)
2 0
MMO 16E1 NG Painel Traseiro
16 Portas E1 75/120 Ω 2 Fontes redundantes full-range 1 Porta Ethernet 10/100 de gerência 4 Entradas de alarmes externos 1 Saída de contato seco 2 portas RS-232 auxiliares
![Page 242: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/242.jpg)
2 1
MMO 16E1 NG Painel Traseiro
1 Porta V.35 / V.36 1 Slot para interfaces adicionais:
– Placa MNG34L com:• 1 porta E3 G.703• 1 porta Ethernet 10/100
2 Slots para transceptores ópticos
![Page 243: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/243.jpg)
2 2
MMO 16E1 NG Painel Frontal
Canal de serviço de voz– Botão de chamada para
acesso rápido Porta RS-232 para console
LCD 16x2 e 4 teclas Leds no painel frontal
– Botão Local/Remoto para acesso ao(s) remoto(s)
![Page 244: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/244.jpg)
2 3
Sem régua de distribuição (DID):• Altura: 44 mm (1U);• Largura: 483 mm (19”);• Profundidade: 215 mm;• Peso: 3,5 kg;
Com régua de distribuição Opcional (DID):• Altura: 81 mm (1,8U);• Largura: 483 mm (19”);• Profundidade: 247 mm;• Peso: 4,0 kg;
MMO 16E1 NG Dimensões
![Page 245: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/245.jpg)
2 4
MMO 16E1 NG Interface Elétrica 2Mbps
Opcional – DID com conectores BNC, IEC 169-13 ou RJ-45
DID - 75 Ohms – Conector IEC169-13 Chaves para aterramento de saída;
![Page 246: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/246.jpg)
2 5
MMO 16E1 NG Interface Elétrica 2Mbps
Opcional – DID com conectores BNC, IEC 169-13 ou RJ-45
DID - 120 Ohms – Conector RJ45
![Page 247: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/247.jpg)
2 6
MMO 16E1 NG Interface Elétrica 2Mbps
Opcional – DID com conectores BNC, IEC 169-13 ou RJ-45
DID - 75 Ohms – Conector IEC169-13 Viabiliza o acesso frontal aos conectores traseiros; Possui 4 conectores RJ45 (ETH) para utilização da placa 4PE Chaves para aterramento de saída;
![Page 248: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/248.jpg)
2 7
2048 kbps ± 50 ppm;
Interfaces G.703 75 ou 120 configurável;
Conector DB17 especial para 4 tributários;
Código de linha HDB3 ou AMI;
MMO 16E1 NG Interface Elétrica 2Mbps
![Page 249: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/249.jpg)
2 8
MMO 16E1 NG Interface Elétrica 2Mbps
Conector DB17
![Page 250: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/250.jpg)
2 9
MMO 16E1 NG Placa Adicional – E3 / Ethernet
Interface E3 + Ethernet 10/100
Interface E3
Interface Ethernet 10/100
![Page 251: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/251.jpg)
3 0
MMO 16E1 NG Placa Adicional – MNG4PE
4 Interfaces Ethernet 10/100
As portas ETH1 e ETH2 operam independentemente do mapeamento dos tributários E1 e dos canais do Inverse Mux. Dividem uma banda de 34Mbps auxiliar que é multiplexada com o sinal de 34Mbps principal gerando um agregado de 68Mbps.
A porta ETH3/ETH4 oferece opção para entrada de até duas interfaces LAN. Opera em modo Inverse Mux com taxa de operação n x 2 Mbps, onde n = 1, 2...16).
![Page 252: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/252.jpg)
3 1
Sinal de 34.368 kbps com desvio máximo de ±20 ppm;
Conector IEC 169-13 ou BNC fêmeas para cabo coaxial.
Código de linha HDB3;
Impedância 75Ω;
MMO 16E1 NG Interface Elétrica – Tributário 34Mbps
![Page 253: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/253.jpg)
3 2
MMO 16E1 NG Interface Ethernet
Velocidade / taxa configurável n x 2 Mbps (até 16 x 2 Mbps); Interface Ethernet 10baseT / 100BaseT Half duplex / Full duplex; Autonegociação; Função Bridge (1024 endereços MAC); Controle de fluxo; Capacidade do buffer: 32 kbytes;
Função LIN (Link Integrity Notification);
![Page 254: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/254.jpg)
3 3
MMO 16E1 NG Interface Ethernet
Suporta pacotes de até 1536 bytes; Função Inverse Mux; Porta MDI-X; Conector RJ-45 Compatível com as normas IEEE 802.3 e 802.1q.
Pode ser mapeado tanto no primeiro quanto no segundo E3
1º E3 Ethernet a N x 2Mbps. Compete com os E1s e V.35;
2º E3 Ethernet a 34Mbps. Compete com o tributário E3.
![Page 255: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/255.jpg)
3 4
MMO 16E1 NG Interface N64
Interface V.35 / V.36 configurável
Conector DB25
Taxas digitais múltiplas de 64 kbps até 2048 kbps (1 ≤ N ≤ 32);
Testes de loopback e BERT pelo painel frontal ou comando;
Detecção de ausência de sinais de dados e relógios;
Taxas digitais múltiplas de 64 kbps até 2048 kbps;
Opera sem quadro ou com quadro (PCM-30 ou PCM-31), com suporte a CRC-4 e CAS;
Opera com relógio interno, recuperado da fibra, externo do ETD ou independente externo;
![Page 256: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/256.jpg)
3 5
Facility Loopback
MMO 16E1NGTestes de Loopback – 2Mbps
E1InterfaceÓptica
MMO16E1NG
Utilizado para testar o cabeamento e conectores
![Page 257: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/257.jpg)
3 6
Remote Loopback
MMO 16E1NGTestes de Loopback – 2Mbps
E1
Interface Óptica
E1
MMO16E1NG MMO16E1NG
![Page 258: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/258.jpg)
3 7
Console:
Verificação do status de inicialização
Réplica do display;
MMO 16E1 NG Acesso via Console
Configuração do Terminal para conexão ao console
Taxa de transmissão: ..... 19200 bps• Bits de dados: ................. 8• Paridade: ......................... Par• Bits de parada: ................ 1• Controle de fluxo: ............ nenhum
![Page 259: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/259.jpg)
3 8
MMO 16E1 NG Acesso via SSH
![Page 260: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/260.jpg)
3 9
MMO 16E1 NG Acesso via Console ou SSH
![Page 261: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/261.jpg)
4 0
MMO 16E1 NGAcesso via Web Browser
![Page 262: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/262.jpg)
4 1
MMO 16E1 NG Software de Gerência SNMPc
![Page 263: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/263.jpg)
4 2
MMO 16E1 NG Acesso via Interface Ethernet
usuários
GERENTE
REDE ETHERNET
![Page 264: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/264.jpg)
4 3
MMO 16E1 NG Acesso via Interface Ethernet
![Page 265: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/265.jpg)
4 4
Configuração mínima necessária para acesso remoto / Web
Endereço Externo IP e máscara;
Endereço Interno IP e máscara;
Rotas;
MMO 16E1 NG Acesso via Interface Ethernet
Todas as demais configurações poderão ser feitas de forma Remota
![Page 266: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/266.jpg)
4 5
Ponto a ponto 1+0
– Interface bidirecional
– Interface unidirecional
MMO 16E1 NG Modo de Operação
![Page 267: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/267.jpg)
4 6
• Anel duplo com proteção automática
Interface bidirecional Interface unidirecional
MMO 16E1 NG Modo de Operação
![Page 268: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/268.jpg)
4 7
5 x E1 (Ch. 1 – 5)
6 x E1Ch. 11 – 16)
16 x E1(Ch. 1 – 16)
5 x E1(Ch. 6 – 10)
Aplicação 1E1s
![Page 269: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/269.jpg)
4 8
5 x E1 (Ch. 1 – 5)
6 x E1 (Ch. 10 – 15)
15 x E1 (Ch. 1 – 15)
4 x E1 (Ch. 6 – 9)
E1 PCM31C Ch. 16 (Ts 1 – 8, 9 – 16, 17 – 28)
V.35 – 768 kbpsE1 PCM31C Ch. 16 (Ts 17 –28)
V.35 – 512 bps E1 PCM31C Ch. 16 (Ts 1 – 8)
V.35 – 512kbpsE1 PCM31C Ch. 16 (Ts 9 –16)
Aplicação 2E1s + V.35
![Page 270: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/270.jpg)
4 9
5 x E1 (Ch. 1 – 5)
6 x E1(Ch. 10 – 15)
15 x E1(Ch. 1 – 15)
4 x E1 (Ch. 6 – 9)
E1 PCM31C Ch. 16 (Ts 1 – 8, 9 – 16, 17 – 28)
E3 G.703
E3 G.703
V.35 – 512 bps E1 PCM31C Ch. 16 (Ts 1 – 8)
V.35 – 512kbpsE1 PCM31C Ch. 16 (Ts 9 –16)
V.35 – 768 kbpsE1 PCM31C Ch. 16 (Ts 17 –28)
Aplicação 3E1s + V.35 + E3
![Page 271: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/271.jpg)
5 0
3 x E1 (Ch. 1 – 3)
3 x E1 (Ch. 7 – 9)
9 x E1 (Ch. 1 – 9)
3 x E1 (Ch. 4 – 6)
E1 PCM31C Ch. 16 (Ts 1 – 8, 9 – 16, 17 – 28)
V.35 – 512 bps E1 PCM31C Ch. 16 (Ts 1 – 8)
V.35 – 512kbpsE1 PCM31C Ch. 16 (Ts 9 –16)
V.35 – 768 kbpsE1 PCM31C Ch. 16 (Ts 17 –28)
E3 G.703
E3 G.703
ETH 10M (5xE1)
ETH 10M (5xE1)
Aplicação 4E1s + V.35 + E3 + Ethernet
![Page 272: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/272.jpg)
5 1
Aplicação 5E1s + V.35 + Ethernet 34 Mbps
5 x E1 (Ch. 1 – 5)
6 x E1 (Ch. 10 – 15)
15 x E1 (Ch. 1 – 15)
4 x E1 (Ch. 6 – 9)
E1 PCM31C Ch. 16 (Ts 1 – 8, 9 – 16, 17 – 28)
Ethernet 34Mbps
Ethernet 34Mbps
V.35 – 512 bps E1 PCM31C Ch. 16 (Ts 1 – 8)
V.35 – 512kbpsE1 PCM31C Ch. 16 (Ts 9 –16)
V.35 – 768 kbpsE1 PCM31C Ch. 16 (Ts 17 –28)
![Page 273: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/273.jpg)
5 2
Aplicação 6 Inverse Mux
4 x E1
E3 G.703 34 Mbps
E3 G.703
5 x E1 .
V.35 - 512 kbps
V.35 - 1024 kbps
9 x E1 (Ch. 1 – 9)1 x E1 PCM30C (Ch. 10) Ethernet 12 Mbps
(inverse Mux - Ch. 11 -16)
Rede E16xE1
Inverse Mux:Atraso máximo fim-a-fim entre tributários:64 / (Número de tributários usados)
16 E1 NGModo InvMux
Ethernet - 12Mbps
Atraso entre tributários de até 10,6 ms
Ethernet 12 Mbps
![Page 274: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/274.jpg)
5 3
Aplicação 7 E1 + Ethernets Nx2M
2 x E1 (Ch. 1 – 2)
9 x E1(Ch. 1 – 9)
4 x E1 (Ch. 6 – 9)
3 x E1(Ch. 3 – 5)
Eth “B” 6 Mbps (Ch. 10 – 12)
Eth “B” 6 Mbps (Ch. 10 – 12)
Eth “A” 8Mbps (Ch. 13 – 16)
Eth “A” 8Mbps (Ch. 13 – 16)
![Page 275: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/275.jpg)
5 4
Aplicação 8 E1 + Ethernet Nx2M + Ethernet 34M
6 x E1 (Ch. 1 – 6)
12 x E1(Ch. 1 – 9)
2 x E1 (Ch. 11 – 12)
4 x E1(Ch. 7 – 10)
Eth 34 Mbps
Eth 34 Mbps
Eth “A” 8Mbps (Ch. 13 – 16)
Eth “A” 8Mbps (Ch. 13 – 16)
![Page 276: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/276.jpg)
5 5
Aplicação 9 Placa Ethernet 4 portas
Cliente #2 – Ax2Mbps
Cliente #1 – 34Mbps
A + E1s ≤ 16
Cliente #2 – Ax2Mbps
Cliente #1 – 34Mbps
Cliente 1 Portas 1 / 2: Utiliza o 2º sinal de 34Mbps Cliente 2 Portas 3 / 4: Utiliza o 1º sinal de 34Mbps (IMX)
![Page 277: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/277.jpg)
5 6
Em Dese
nvolv
imen
to
Aplicação 10 Placa Ethernet 4 portas
Cliente #3 – Cx2MbpsCliente #2 – Bx2Mbps
Cliente #1 – Ax2Mbps
Cliente #4 – Dx2Mbps
A+B ≤ 16
C+D+E1s ≤ 16
Cliente #3 – Cx2MbpsCliente #2 – Bx2Mbps
Cliente #1 – Ax2Mbps
Cliente #4 – Dx2Mbps
Porta 1 e 2: Utilizam o 2º sinal de 34MbpsPorta 3 e 4: Utilizam o 1º sinal de 34Mbps (IMX)Os tráfegos são separados por VLAN
![Page 278: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/278.jpg)
5 7
LINHA CONVERSORES DE MEIO
![Page 279: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/279.jpg)
5 8
MECÂNICAS DOS CONVERSORES Chassi 1
Chassi de 1 slot
![Page 280: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/280.jpg)
5 9
• Alimentação Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarização ajustada automaticamente para alimentação DC.
• Possibilidade de redundância de fonte;
• Configuração local via Dip-switch;
• Suporta supervisão e gerência SNMP remotas;
• Mecânica: 9.5” por 1U.
Chassi de 1 slot
MECÂNICAS DOS CONVERSORES Chassi 1
![Page 281: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/281.jpg)
6 0
Chassi de 3 slots
MECÂNICAS DOS CONVERSORES Chassi 3
![Page 282: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/282.jpg)
6 1
Chassi de 3 slots
• Alimentação Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarização ajustada automaticamente para alimentação DC.
• Possibilidade de redundância de fonte através da placa CMFT;
• Configuração local via Dip-switch;
• Gerência SNMP através da placa CMGR;
• Configuração e verificação de status via Web Browser (CMGR);
• Mecânica: 19” por 1U.
MECÂNICAS DOS CONVERSORES Chassi 3
![Page 283: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/283.jpg)
6 2
Chassi de 16 slots
• CH-16 com placas filtro
MECÂNICAS DOS CONVERSORES Chassi 16
![Page 284: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/284.jpg)
6 3
Chassi de 16 slots
• CH-16 sem placas filtro e 17° slot disponível
MECÂNICAS DOS CONVERSORES Chassi 16
![Page 285: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/285.jpg)
6 4
• Alimentação Full Range DC: -36 a -60Vdc; AC: 90 a 250 Vac;
• Polarização ajustada automaticamente para alimentação DC;
• Possibilidade de redundância de fonte através da placa CMFT (fornece energia para até 4 placas);
• Configuração local via Dip-switch;
• Gerência SNMP através da placa CMGR;
• Configuração e verificação de status via Web Browser (CMGR);
• Mecânica: 19” por 4U
Chassi de 16 slots
MECÂNICAS DOS CONVERSORES Chassi 16
![Page 286: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/286.jpg)
6 5
CMGR
![Page 287: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/287.jpg)
6 6
CMGRApresentação
AsGaCMGR
TEST RST
ON
S
R
L
AUX IN19200,8,E,1ETHERNETAUX OUT
Painel Frontal
![Page 288: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/288.jpg)
6 7
Os conversores de meios da AsGa são gerenciados via protocolo SNMP (V1, V2 e V3) através da placa CMGR.
A configuração e verificação de status são realizadas via Web Browser.
Gerência das placas remotas àquelas localizadas no bastidor local.
Extensão de gerência para até 7 mecânicas de conversores de meios através da CMMEG (placa opcional).
Gerência de até 100 placas dos conversores de meios.
Alimentação de emergência para 1 placa dos conversores de meios, caso a fonte interna dessa apresente falha.
CMGRApresentação
![Page 289: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/289.jpg)
6 8
Configuração, Supervisão e Gerência de Alarmes (SNMP) RJ-45
10/100 BaseT
Leds indicativos do estado da interface Ethernet:L – Led indicativo de link EthernetS – Velocidade da interface EthernetR – Led indicativo de recepção de dados através da interface Ethernet
CMGRInterface Ethernet
AsGaCMGR
TEST RST
ON
S
R
L
AUX IN19200,8,E,1ETHERNETAUX OUT
![Page 290: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/290.jpg)
6 9
Cada placa dos Conversores possui uma fonte interna.
Alimentação Full-Range:
• DC: - 48V ± 25% (-36 a -60 VDC)
• AC: 90 ~ 250 VAC
Opção de fonte redundante na mecânica;
Consumo: 6W.
CMGRAlimentação
![Page 291: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/291.jpg)
7 0
Inicialmente alguns parâmetros devem ser alterados localmente, via terminal VT100, para se ter acesso à placa CMGR através da rede Ethernet.
CMGRConfiguração Inicial
-------------------------------------------------------------------------
AsGa CMGR - STATUS
Identification....: CH16 - cliente X Date..............: 05/07/2005 Time..............: 17:16:39 IP Address........: 192.168.30.14 Mask Address......: 255.255.255.224 Gateway...........: 192.168.30.1 Hardware Version..: 2.0 Software Version..: 1.0 Firmware Version..: 1.0 CmGr Configuration: SAVED Description.......: CH-16 localizado no predio 2, 5o andar, bastidor 3 ------------------------------------------------------------------------- Configuration: [1]Identification [2]Network [3]Description [4]Save [5]Logout -------------------------------------------------------------------------
Choose one of the options above:
Taxa de transmissão: 19200 baudsBits de dados: 8Paridade: ParBits de parada: 1Controle de fluxo: nenhum
Configuração do Terminal
![Page 292: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/292.jpg)
7 1
CMGR Configuração via Web-Browser
Configuração do CMGR e das Placas dos Conversores
Home
![Page 293: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/293.jpg)
7 2
CMGR Configuração via Web-Browser
CMGR
![Page 294: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/294.jpg)
7 3
CMGR Configuração via Web-Browser
Managed Boards
![Page 295: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/295.jpg)
7 4
CMSTM-1
![Page 296: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/296.jpg)
7 5
CMSTM-1Apresentação
Painel Frontal
![Page 297: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/297.jpg)
7 6
Conversão de um sinal elétrico STM-1 (hierarquia SDH), para comunicação via fibras ópticas.
Interface STM-1
• Velocidade: 155,4 Mb/s
• Código: CMI.
Opção de redundância óptica;
Exteriorização de alarmes e status através de leds;
Facilidades de testes, controle e gerência do equipamento local e remoto;
Opção de gerência SNMP através da placa CMGR (para bastidor de 3 ou 16 posições).
CMSTM-1Apresentação
![Page 298: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/298.jpg)
7 7
CMSTM-1 Apresentação
Unidirecional
Unidirecional com redundância
Bidirecional
![Page 299: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/299.jpg)
7 8
STM-1 - 155,4 Mb/s com desvio máximo de ±20 ppm
Código de linha CMI
Impedância 75Ω;
Conector IEC 169-13 ou BNC fêmeas para cabo coaxial.
CMSTM-1 Interface Elétrica
![Page 300: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/300.jpg)
7 9
O CMSTM-1 com a configuração de fábrica já está pronto para operação.
As configurações de gerência são realizadas via Web Browser através da placa de gerência CMGR (Gerência dos Conversores de Meios da AsGa).
CMSTM-1 Configuração
![Page 301: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/301.jpg)
8 0
Botão TEST De acordo com o tempo de acionamento do botãoTEST, pode-
se realizar 5 testes.
CMSTM-1 Operação – Testes e Reset
![Page 302: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/302.jpg)
8 1
CMSTM-1 Operação – Testes e Reset
TESTE 1 Aciona um Remote Loopback na interface elétrica da placa
remota.
LIU LIU
Placa local Placa remota
M M
B BFibras
RemoteLoopback
![Page 303: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/303.jpg)
8 2
CMSTM-1 Operação – Testes e Reset
TESTE 2 Aciona um Facility Loopback na interface elétrica da placa
local.
LIU LIU
Placa local Placa remota
M M
B BFibras
FacilityLoopback
![Page 304: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/304.jpg)
8 3
CMSTM-1 Operação – Testes e Reset
TESTE 3 Aciona um Remote Loopback na interface elétrica da placa
local.
LIU LIU
Placa local Placa remota
M M
B BFibras
RemoteLoopback
![Page 305: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/305.jpg)
8 4
CMSTM-1 Operação – Testes e Reset
TESTE 4 Aciona o Teste de Integridade de Enlace e Remote Loopback
nas interfaces elétricas das placas local e remota.
LIU
Placa local
BFibras
RemoteLoopback LIU
Placa remota
M
BRemote
Loopback
M
![Page 306: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/306.jpg)
8 5
CMSTM-1 Operação – Testes e Reset
TESTE 5 Aciona o Teste de Integridade de Enlace. Neste caso, são necessários loops físicos na interface dos
CMSTM-1 local e remoto. Estes loops devem ser colocados antes da execução do teste.
LIU
Placa local
BFibras
LoopbackFísico LIU
Placa remota
M
B
LoopbackFísicoM
![Page 307: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/307.jpg)
8 6
CMETH
![Page 308: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/308.jpg)
8 7
CMETHApresentação
Painel Frontal
![Page 309: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/309.jpg)
8 8
Conversão de sinal elétrico 10/100BaseTx para sinal óptico 100BaseFx;
Opção de redundância óptica;
Exteriorização de alarmes e status através de leds;
Facilidades de testes, controle e gerência do equipamento local e remoto;
Opção de gerência SNMP através da placa CMGR (para bastidor de 3 ou 16 posições).
CMETHApresentação
![Page 310: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/310.jpg)
8 9
INOUT
AsGa
OPTICAL
CMETH T EST R ST
O N
FC
LOS
LK
100
FD
LKETHERNET
REM LOC
CMETHApresentação
Unidirecional
Unidirecional com redundância
Bidirecional
![Page 311: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/311.jpg)
9 0
Porta MDI-X;
RJ-45;
Configuração através de dip-switch ou software;
Parâmetros de configuração:
Auto-negociação
Velocidade (10 / 100Mbps)
Modo (half / full duplex)
Controle de fluxo UTP e óptico
LIN (Link Integrity Notification)
CMETHInterface Ethernet
![Page 312: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/312.jpg)
9 1
CMETHLIN (Link Integrity Notification)
![Page 313: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/313.jpg)
9 2
As configurações dos parâmetros são realizadas através da dip-switch de 8 chaves presente na parte interna do cartão (CH3).
CMETHConfiguração via Dip-switch
1 2 3 4 ON
OFF
5 6 7 8
![Page 314: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/314.jpg)
9 3
Chaves Posição Configuração
Ch1 ONOFF
Auto-negociação habilitadaAuto-negociação desabilitada
Ch2 ONOFF
Velocidade 100MbpsVelocidade 10Mbps
Ch3 ONOFF
Modo Full-duplexModo Half-duplex
Ch4 ONOFF
Controle de Fluxo UTP habilitadoControle de Fluxo UTP desabilitado
Ch5 ONOFF
Gerência habilitadaGerência desabilitada
Ch6 ONOFF
Link Integrity Notification (LIN) habilitadoLink Integrity Notification (LIN) desabilitado
Ch7 ONOFF
Interface Óptica Reserva habilitadaInterface Óptica Reserva desabilitada
Chaves Posição Configuração
CMETHConfiguração via Dip-switch
![Page 315: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/315.jpg)
9 4
Botão TEST De acordo com o tempo de acionamento do botãoTEST,
podemos realizar 2 testes
Tempo de acionamento
Teste
Menor que 3 segundos
Desabilita o teste em execução / informa versão de software, firmware e tipo de
configuração
Teste 1 Entre 3 e 6 segundos
Remote Loopback no CMETH local
Tempo de acionamento
Teste
CMETHOperação – Testes e Reset
![Page 316: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/316.jpg)
9 5
Placa local
BFibrasópticas
RemoteLoopback
Placa remota
M
B
MInterface Elétrica
Remote Loopback
CMETHOperação – Testes e Reset
![Page 317: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/317.jpg)
9 6
Placa local
BFibrasópticas
FacilityLoopback
Placa remota
M
B
MInterface Elétrica
Facility Loopback
CMETHOperação – Testes e Reset
![Page 318: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/318.jpg)
9 7
CMETH Aplicações
![Page 319: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/319.jpg)
9 8
CME3
![Page 320: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/320.jpg)
9 9
INOUT STSINOUT
M
B
E
G.703 34Mb/s
AsGaINOUT
MAIN BACK UP
CME3
TEST RST
ON
CME3Apresentação
Painel Frontal
![Page 321: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/321.jpg)
1 0 0
Conversão de sinal elétrico digital de 34.368 kbps para um sinal óptico apropriado para comunicação via fibras ópticas;
Opção de redundância óptica;
Exteriorização de alarmes e status através de leds;
Facilidades de testes, controle e gerência do equipamento local e remoto;
Opção de gerência SNMP através da placa CMGR (para bastidor de 3 ou 16 posições).
CME3Apresentação
![Page 322: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/322.jpg)
1 0 1
CME3Apresentação
INOUT STSINOUT
M
B
E
G.703 34Mb/s
AsGaINOUT
MAIN BACK UP
CME3
TEST RST
ON
INOUT STSEL
G.703 34Mb/s
AsGaINOUT
MAIN
CME3
TEST RST
ONOP
Unidirecional com redundância
Unidirecional sem redundância
![Page 323: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/323.jpg)
1 0 2
Sinal de 34.368 kbps com desvio máximo de ±20 ppm;
Código de linha HDB3;
Impedância 75Ω;
Conector IEC 169-13 ou BNC fêmeas para cabo coaxial.
CME3Interface Elétrica
![Page 324: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/324.jpg)
1 0 3
As configurações dos parâmetros são realizadas através da dip-switch de 4 chaves presente na parte interna do cartão (SW3).
CME3Configuração via Dip-switch
1 2 3 4 ON
OFF
![Page 325: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/325.jpg)
1 0 4
CME3Configuração via Dip-switch
Chave 1 Realização de testes
ON Desabilitada
Chave 1 Realização de testes
Habilita-se ou desabilita-se a realização de testes de loopback e de integridade no enlace.
Chave 1
![Page 326: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/326.jpg)
1 0 5
CME3Configuração via Dip-switch
No caso do CME3 com proteção, a interface óptica reserva pode ser desabilitada e o sistema passa a operar sem proteção.
Chave 2
Chave 2 Modo de Operação
ON Sem proteção (1+0)
Chave 2 Modo de Operação
![Page 327: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/327.jpg)
1 0 6
CME3Configuração via Dip-switch
Tempo de Retorno da comutação.
Chave 3 e 4
Chave 3 Chave 4 Tempo de RetornoOFF OFF 10 segundos
OFF ON 10 minutos
ON OFF 15 minutos
Chave 3 Chave 4 Tempo de Retorno
![Page 328: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/328.jpg)
1 0 7
Botão TEST De acordo com o tempo de acionamento do botãoTEST, pode-
se realizar 5 testes.
CME3Operação – Testes e Reset
Tempo de acionamento TesteMenor que 3 segundos Desabilita o teste em execução / apresenta
os alarmes do CME3 remoto.
Teste 1 Entre 3 e 6 segundos Remote Loopback no CME3 remoto
Teste 2 Entre 6 e 9 segundos Facility Loopback no CME3 local
Teste 3 Entre 9 e 12 segundos Remote Loopback no CME3 local
Teste 4 Entre 12 e 15 segundos Teste de integridade de enlace com Remote Loopback
Teste 5 Entre 15 e 18 segundos Teste de integridade de enlace
Tempo de acionamento Teste
![Page 329: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/329.jpg)
1 0 8
CME3Operação – Testes e Reset
TESTE 1 Aciona um Remote Loopback na interface elétrica da placa
remota.
LIU LIU
Placa local Placa remota
M M
B BFibras
RemoteLoopback
![Page 330: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/330.jpg)
1 0 9
CME3Operação – Testes e Reset
TESTE 2 Aciona um Facility Loopback na interface elétrica da placa
local.
LIU LIU
Placa local Placa remota
M M
B BFibras
FacilityLoopback
![Page 331: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/331.jpg)
1 1 0
CME3Operação – Testes e Reset
TESTE 3 Aciona um Remote Loopback na interface elétrica da placa
local.
LIU LIU
Placa local Placa remota
M M
B BFibras
RemoteLoopback
![Page 332: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/332.jpg)
1 1 1
CME3Operação – Testes e Reset
TESTE 4 Aciona o Teste de Integridade de Enlace e Remote Loopback
nas interfaces elétricas das placas local e remota.
LIU
Placa local
BFibras
RemoteLoopback LIU
Placa remota
M
BRemote
Loopback
M
![Page 333: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/333.jpg)
1 1 2
CME3Operação – Testes e Reset
TESTE 5 Aciona o Teste de Integridade de Enlace. Neste caso, são necessários loops físicos na interface dos
CME3 local e remoto. Estes loops devem ser colocados antes da execução do teste.
LIU
Placa local
BFibras
LoopbackFísico LIU
Placa remota
M
B
LoopbackFísicoM
![Page 334: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/334.jpg)
1 1 3
CONTATOSuporte Técnico
Para maiores informações acesse:
www.asga.com.br
ou entre em contato com o Suporte Técnico:
[email protected](19) 2116-2040
![Page 335: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/335.jpg)
Chassi de 1 posição Chassi de 3 posições Chassi de 16 posições
• Alimentação Full Range: DC 48 V; AC110 V / 220V.
• Redundância de fonte de alimentação opcional.
• Supervisão e gerenciamento das unidades locais e remotas.
• Gerenciamento SNMP através da placa CMGR (CH16 e CH3) opcional.
• Configuração via dip-switch (local) ou WebBrowser (através da placa CMGR).
• Possibilidade de cascateamento de gerência para até 7 chassis.
Conversores de Meios
![Page 336: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/336.jpg)
• Conversor de sinal elétrico 10/100BaseTx para um sinal óptico 100BaseFx, para comunicação via fibras ópticas
• Interface Ethernet
• 10 / 100Mbps, Half / Full duplex
• Auto-negociação de velocidade, Full/half duplex e controle de fluxo
• LIN “Link Integrity Notification”
• VLAN
• Interface Óptica
• Interface Multimodo,
• Interface Monomodo Bidirecional/unidirecional
• Operação com proteção óptica opcional
CMETH
![Page 337: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/337.jpg)
CMETHAplicações
![Page 338: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/338.jpg)
• Conversão de um sinal elétrico E3 G.703 em um sinal óptico para comunicação via fibras ópticas
• Interface E3
• Velocidade: 34.368 kb/s
• Código: HDB3
• Interface Óptica
• Interface Multimodo
• Interface Monomodo unidirecional / bidirecional
• Operação com proteção óptica opcional
CME3
![Page 339: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/339.jpg)
• Conversão de um sinal elétrico STM-1 (hierarquia SDH), para comunicação via fibras ópticas.
• Interface STM-1
• Velocidade: 155,4 Mb/s
• Código: CMI.
• Interface Óptica.
• Interface Multimodo.
• Interface Monomodo unidirecional / bidirecional.
• Operação com proteção óptica opcional
CMSTM-1
![Page 340: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/340.jpg)
• Conversão de sinais de taxas nx64 kb/s, com interface V.35/V.36, para sinal E1 estruturado (G.704) ou para sinal E1 não estruturado (G.703).
• Interface nx64 kb/s
• Protocolos V.35 e V.36 ou Multiprotocolo V.35 e V.36 V.28, X21, RS530, RS530A ou V.11
• Interface Elétrica E1 (RJ-45).
• 2Mb/s - G.703 (75 Ohms ou 120 Ohms)
• Código: HDB3
CMN64
![Page 341: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/341.jpg)
• Conversão de um sinal Ethernet 10/100BaseT para uma interface G.703 E1
• Interfaces Ethernet
• 10 / 100Mbps, Half / Full duplex
• Auto-negociação de velocidade, Full/half duplex e controle de fluxo
• LIN “Link Integrity Notification”
• Transparente a VLAN
• Interface E1.
• 2Mb/s - G.703 (75 Ohms ou 120 Ohms)
• Código: HDB3
CMDTC2
![Page 342: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/342.jpg)
• Conversão de um sinal Ethernet 10/100BaseT para uma interface G.703 E3 ou DS3
• Interfaces Ethernet
• 10 / 100Mbps, Half / Full duplex
• Auto-negociação de velocidade, Full/half duplex e controle de fluxo
• LIN “Link Integrity Notification”
• Transparente a VLAN
• Interface E3 / DS3
• Velocidade: 34 Mb/s ou 45 Mb/s
CMDTCH
![Page 343: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/343.jpg)
CMGE
• Conversor de sinal elétrico 10/100/1000BaseTx para um sinal óptico 1000BaseFx, para comunicação via fibras ópticas
• Interface Ethernet
• 10 / 100 / 1000 Mbps, Half / Full duplex
• Auto-negociação de velocidade, Full/half duplex e controle de fluxo
• LIN “Link Integrity Notification”
• VLAN
• Capacidade para pacotes “Jumbo”
• Interface Óptica
• Operação com proteção óptica opcional
![Page 344: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/344.jpg)
CMGR
• Os conversores de meios da AsGa são gerenciados via protocolo SNMP (V1, V2 e V3) através da placa CMGR
• A configuração e verificação de status são realizadas via Web Browser
• Gerencia também as placas remotas àquelas localizadas no bastidor local
• Extensão de gerência para até 7 mecânicas de conversores de meios através da CMMEG (placa opcional)
• Gerência de até 100 placas dos conversores de meios
![Page 345: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/345.jpg)
CMGR
• Configuração via WebBrowser
![Page 346: asga 2013-10-14_04-16-4292564 2](https://reader034.fdocuments.mx/reader034/viewer/2022052117/55cf93b9550346f57b9e324a/html5/thumbnails/346.jpg)